首页> 外文期刊>Iranian Journal of Radiology >DIAGNOSTIC ACCURACY OF DIGITAL AND CONVENTIONAL RADIOGRAPHY IN THE DETECTION OF NON-CAVITATED APPROXIMAL DENTAL CARIES BACKGROUND: RADIOGRAPHY PLAYS AN IMPORTANT ROLE IN THE DETECTION OF INTERPROXIMAL CARIES
【24h】

DIAGNOSTIC ACCURACY OF DIGITAL AND CONVENTIONAL RADIOGRAPHY IN THE DETECTION OF NON-CAVITATED APPROXIMAL DENTAL CARIES BACKGROUND: RADIOGRAPHY PLAYS AN IMPORTANT ROLE IN THE DETECTION OF INTERPROXIMAL CARIES

机译:数字和常规放射线照相在非空洞性近牙龋中的诊断准确性背景:放射线照相在检出近牙龋中起重要作用

获取原文
       

摘要

Objectives: The aim of the present study was to determine diagnostic accuracy of chargecoupled devices (CCD), Photo Stimulable Phosphor (PSP) and film radiography in detecting non-cavitated caries.Patients and Methods: Seventy-two non-cavitated approximal surfaces of extracted human posterior teeth were radiographed under standardized conditions using three intraoral modalities: CCD Dixi3 (Planmeca ? Finland), PSP Digora PCT (Soredex, Finland), and E-speed film (Kodak, USA). Radiographs were interpreted by four observers and caries lesions were classified as sound (R0), restricted to enamel (R1) , reaching the dentin enamel junction (DEJ) and the outer half of the dentin (R2) and the inner half of the dentin (R3). The teeth were subsequently sectioned for histological analysis which served as the gold standard for radiographic examination.Results: Microscopic examinations showed that the distribution of caries were 63.9% sound, 18.1% enamel, 9.7% DEJ and outer half of the dentin and 8.3% into the inner half of the dentin. The sensitivity and specificity of film, CCD and PSP for the detection of enamel caries were 38% and 98%; 15% and 96%; and 23% and 98% , respectively. The sensitivity and specificity of film , CCD and PSP for the detection of both dentin and enamel caries were 55% and 100%; 45% and 100%; and 55% and 100%, respectively.Conclusions: The results demonstrated that the diagnostic accuracy of digital images is similar to that of conventional film radiography in the detection of non-cavitated approximal caries.
机译:目的:本研究的目的是确定电荷耦合器件(CCD),光刺激荧光体(PSP)和胶片X射线照相法在检测非空洞龋中的诊断准确性。患者和方法:72个非空洞的近似提取表面使用三种口腔内模在标准条件下对人体后牙进行X线照相:CCD Dixi3(芬兰普兰梅卡),PSP Digora PCT(芬兰索德克斯)和E-speed胶片(美国柯达)。放射线照片由四名观察员解释,龋损分为声音(R0),局限于牙釉质(R1),到达牙本质牙釉质交界处(DEJ),牙本质的外半部(R2)和牙本质的内半部(R2)。 R3)。结果:显微镜检查显示,龋齿的分布为声音的63.9%,牙釉质的18.1%,牙本质的9.7%,牙本质的外半部和牙龈的分布,分别为8.3%和6.3%。牙本质的内侧。膜,CCD和PSP对牙釉质龋检测的敏感性和特异性分别为38%和98%; 15%和96%;和23%和98%。膜,CCD和PSP对检测牙本质和牙釉质龋的敏感性和特异性分别为55%和100%; 45%和100%;结论:结果表明,在检测非空洞性龋齿中,数字图像的诊断准确性与常规胶片X射线照相法相似。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号