The majority of research is about the detection of broken bar fault in three-phase induction motor at high slip. Thus, it becomes very interesting and demanding to detect faults in caseof low slip range. In this study, a novel investigation of broken bar faults using instantaneous power is presented. The method is based on calculations and frequency analysis of partial and total instantaneous power under low slip range. The used model of squirrel cage induction machine takes into account the geometry and winding layout. This model will be used to analyze the impact of broken bar on instantaneous power spectrum. The proposed ideas in this paper are veri?ed experimentally. The results show that broken bar fault can be more reliably detected under low slip range when using a large frequency area of both partial and total instantaneous power spectrums.
机译:大多数研究是关于在高滑移率下检测三相感应电动机断条故障的研究。因此,在低滑差范围的情况下检测故障变得非常有趣并且要求。在这项研究中,提出了一种利用瞬时功率对断条故障进行新颖的研究。该方法基于低滑差范围下的部分和全部瞬时功率的计算和频率分析。鼠笼式感应电机的使用模型考虑了几何形状和绕组布局。该模型将用于分析折线对瞬时功率谱的影响。本文提出的想法已通过实验验证。结果表明,当同时使用部分和全部瞬时功率谱的较大频率区域时,在低滑动范围内可以更可靠地检测出断条故障。