摘要

Single-core underground power cables with two-points bonding induce currents in their metallic sheaths. The sheath induced currents are undesirable and generate power losses and reduce the cable ampacity. This paper has shown that the values of the sheath losses in some cases could be greater than conductor losses, depending on various factors. Such these factors are type of cable layouts, cable parameters, cable spacing, sheath resistance, phase rotation, conductor current and cable armoring. In this paper the above factors have been investigated. The calculations are carried out depending mainly on IEC 60287 by a proposed computer program using MATLAB. Keywords: Single-core cables, two-point bonding method, sheaths losses, flat, trefoil, armoring
机译:具有两点粘结的单芯地下电力电缆在其金属护套中感应出电流。护套感应电流是不希望的,会产生功率损耗并降低电缆载流量。本文表明,在某些情况下,取决于各种因素,护套损耗的值可能大于导体损耗。这些因素包括电缆布局的类型,电缆参数,电缆间距,护套电阻,相旋转,导体电流和电缆铠装。本文对以上因素进行了研究。通过使用MATLAB的拟议计算机程序主要根据IEC 60287进行计算。关键字:单芯电缆,两点结合法,护套损耗,扁平,三叶,铠装