The purposes of this study were to recalibrate a new motion sensor wristband (ViM sports memory: ViM) to metabolic equivalents (METs) during walking and running, and to examine the cross-validity of the recalibration model. Forty-five healthy Japanese (23 males and 22 females) voluntarily participated in this study. The participants were divided into two groups: a recalibration group (16 males and14 females) and a cross-validity group (7 males and 8 females). The participants performed 5 min of treadmill walking at 3.6, 4.8, and 6.0 km/h, and treadmill running at 7.2, and 9.6 km/h. The ViM was placed on the non-dominant wrist. Simultaneous measurements of the ViM and an indirect calorimeter (IC) were continuously recorded during all exercises. The recalibration models were calculated for males and females from data of the recalibration group using general linear mixed model. The cross-validity was examined by correlation coefficients, repeated ANOVA, and paired t-test adjusted by Bonferroni's method. In the recalibration group, the recalibration models showed high determination coefficients (male: R ~(2)=0.74, SEE=1.51 METs; females: R ~(2)=0.84, SEE=1.16 METs). In the cross-validation group, there were significant correlation coefficients at 3.6, 4.8, 6.0, and 9.6 km/h (r >=0.56, p <0.001). Differences (?4 to 13%) between the IC measurements and the recalibration model estimations were not significant (p >0.185) at any speed. These results showed that the recalibration model improved the validity and accuracy of the ViM.
机译:这项研究的目的是在步行和跑步过程中将新的运动传感器腕带(ViM运动记忆:ViM)重新校准为代谢当量(MET),并检验重新校准模型的交叉有效性。四十五名健康的日本人(男23名,女22名)自愿参加了这项研究。参与者分为两组:重新校准组(男性16位,女性14位)和交叉验证组(男性7位,女性8位)。参与者以3.6、4.8和6.0 km / h的速度走了5分钟的跑步机,以7.2和9.6 km / h的速度走了跑步机。将ViM放在非优势手腕上。在所有锻炼过程中,均连续记录ViM和间接热量计(IC)的同时测量值。使用通用线性混合模型,根据重新校准组的数据计算男性和女性的重新校准模型。通过相关系数,重复方差分析和通过Bonferroni方法调整的配对t检验来检验交叉有效性。在重新校准组中,重新校准模型显示出较高的确定系数(男性:R〜(2)= 0.74,SEE = 1.51 METs;女性:Ri(〜2)= 0.84,SEE = 1.16 METs)。在交叉验证组中,相关系数分别为3.6、4.8、6.0和9.6 km / h( = 0.56, p <0.001)。在任何速度下,IC测量值与重新校准模型估计值之间的差异(?4至13%)均不显着(> 0.185)。这些结果表明,重新校准模型提高了ViM的有效性和准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号