One of the commercially available capillary-based microfluidic synthesizers is Advion NanoTek Microfluidic Synthesis System and is currently being used across the globe. The goal of this study is to demonstrate the system capability to perform the synthesis of two compounds sequentially without cleaning the equipment between the syntheses. We have chosen to prepare two key radiotracers [F-18]FLT and [F-18]FMISO. The basic microfluidic flow chemistry module was reconfigured to allow the hydrolysis of the second tracer in a vial using reactor 1 as a heat source and the system was integrated to semi-preparative high-performance liquid chromatography with a column selector and solvent selector. The decay corrected radio chemical yields of [~(18)F]FLT and [~(18)F]FMISO were found to be 28.5% and 38.6% respectively. The specific activity was determined to be >2 Ci/ μ mol.
机译:Advion NanoTek微流体合成系统是市售的基于毛细管的微流体合成器之一,目前已在全球范围内使用。这项研究的目的是证明无需清洗合成装置之间的设备即可连续进行两种化合物合成的系统能力。我们选择准备两个关键的放射性示踪剂[F-18] FLT和[F-18] FMISO。重新配置了基本的微流化学模块,以使用反应器1作为热源,使小瓶中的第二种示踪剂水解,并将该系统集成到具有柱选择器和溶剂选择器的半制备高效液相色谱仪中。经衰变校正的[〜(18)F] FLT和[〜(18)F] FMISO的放射化学产率分别为28.5%和38.6%。确定比活度> 2 Ci /μmol。