...
首页> 外文期刊>International Journal of Preventive Medicine >Prevention of Cross-contamination Risk by Disinfection of Irreversible Hydrocolloid Impression Materials with Ozonated Water
【24h】

Prevention of Cross-contamination Risk by Disinfection of Irreversible Hydrocolloid Impression Materials with Ozonated Water

机译:通过用臭氧水消毒不可逆的水胶体印象材料来预防交叉污染的风险

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Background: Disinfection of dental impression is mandatory for preventing the cross infection between dental staff and dental laboratory. Ozone as a disinfectant can be used in various ways in dentistry. The aim of this study was to evaluate the efficacy of ozonated water for disinfection of irreversible hydrocolloid impression materials and preventing cross-contamination. Methods: Thirty-two circular specimens (1 cm diameter and 2 mm thickness) of irreversible hydrocolloid impression material were made. Thirty specimens were contaminated with Pseudomonas aeruginosa (ATCC 27853), Staphylococcus aureus (ATCC 51299), and Candida albicans (PTCC 5027). Except control samples ( n = 2), the other specimens were immersed in ozonated water for 5 and 10 min (5 sample each group). Trypsin was used for separating microorganisms. Diluted microbial solution was analyzed microbiologically for colony-forming units (CFUs). Two-way repeated measure ANOVA and Scheffe post hoc test were used for data analysis (α = 0.05). Results: The number of CFUs after disinfection with ozonated water was decreased significantly (11.84%, 61.55%, and 20.27% after 5 min and 11.03%, 14.50%, and 16.99% after 10 min for P. aeruginosa , S. aureus , and C. albicans , respectively) ( P 0.001). Increasing the time of disinfection resulted in significant reduction in a number of S. aureus only ( P 0.001) although they did not vanish microorganisms completely. Conclusions: Immersion of irreversible hydrocolloid impression material in ozonated water for 10 min will not lead to complete disinfection but decreases the microorganisms to a level that can prevent infection transmission.
机译:背景:为了防止牙科人员与牙科实验室之间发生交叉感染,必须对牙齿印模进行消毒。臭氧可以在牙科领域以多种方式使用。这项研究的目的是评估臭氧水对不可逆水胶体印模材料消毒和防止交叉污染的功效。方法:制作了32个圆形样品(直径1厘米,厚度2毫米)不可逆的水胶体印模材料。 30个标本被铜绿假单胞菌(ATCC 27853),金黄色葡萄球菌(ATCC 51299)和白色念珠菌(PTCC 5027)污染。除对照样品(n = 2)外,将其他样品浸入臭氧水中5分钟和10分钟(每组5个样品)。胰蛋白酶用于分离微生物。对稀释的微生物溶液进行了菌落形成单位(CFU)的微生物学分析。使用双向重复测量方差分析和席夫事后检验进行数据分析(α= 0.05)。结果:用臭氧水消毒后的CFU数量显着减少(铜绿假单胞菌,金黄色葡萄球菌和铜绿假单胞菌5分钟后分别为11.84%,61.55%和20.27%,10分钟后分别为11.03%,14.50%和16.99%)。分别为白色念珠菌(P <0.001)。增加消毒时间只会导致大量金黄色葡萄球菌的减少(P <0.001),尽管它们不能完全消除微生物。结论:不可逆的水胶体印模材料在臭氧水中浸泡10分钟不会导致完全消毒,但会将微生物减少到可以防止感染传播的水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号