首页> 外文期刊>International Journal of Pharmaceutical Sciences and Research >KANENGISER'S EVALUATION METHOD: AN EFFICIENT METHOD FOR DETERMINING OCULAR IRRITANT POTENTIAL IN COSMETICS
【24h】

KANENGISER'S EVALUATION METHOD: AN EFFICIENT METHOD FOR DETERMINING OCULAR IRRITANT POTENTIAL IN COSMETICS

机译:KANENGISER的评估方法:测定化妆品中刺激性电位的有效方法

获取原文
           

摘要

A growing interest in usage of cosmetics has created the need for greater precision in evaluation and has stimulated research into cosmetic medicine. Ocular irritation testing represents an important step in the safety evaluation of cosmetic products. The objective of this study was to introduce a method of assessing ocular irritancy in human subjects and to illustrate the significance of a new expanded grading system, designed by Kanengiser, for the precise evaluation of ocular lesions and quantitative assessment of ocular surface responses to cosmetic products. Evaluation procedure is carried out using acute instillation method. A scoring scale for Palpebral Conjunctival Irritation, Eyelid Irritation, Lachrymation, Subjective Irritation, Bulbar Conjunctival Irritation, Corneal Abnormalities, Palpebral and Bulbar Conjunctival, Caruncular, and Corneal Fluorescein Ophthalmic Staining was designed by Kanengiser & observations are interpreted graphically. From the observations it is evident that frequency of occurrence of adverse events is minimal in the human ocular instillation studies. The area of corneal fluorescein staining was judged on a 0 to +4 scale using the same terminology as for corneal cloudiness (Draize). The statistical analysis of correlation between subjective irritation levels and area levels of corneal staining demonstrated better correlation for Kanengiser's scoring system (r = 0.82) than for Draize's scoring system (r = 0.74). From the above data we can illustrate that Kanengiser's ocular grading system is an efficient, 'evaluation method for determining the ocular irritant potential of cosmetic products in human eyes'
机译:对化妆品使用的兴趣日益增长,这就要求对评估的准确性进行更高的要求,并刺激了对化妆品医学的研究。眼睛刺激性测试是化妆品安全性评估中的重要一步。这项研究的目的是介绍一种评估人眼刺激性的方法,并说明由Kanengiser设计的新型扩展分级系统对精确评估眼部病变和定量评估对化妆品的眼表反应的重要性。 。评估程序使用急性滴注法进行。 Kanengiser设计了睑结膜刺激性,眼睑刺激性,泪液性,主观刺激性,球结膜刺激性,角膜异常性,睑板和球结膜刺激性,角膜和角膜荧光素眼科染色的评分量表,并以图形方式解释了观察结果。从观察结果可以明显看出,在人眼滴注研究中,不良事件的发生频率是最小的。使用与角膜混浊(Draize)相同的术语,以0至+4的等级来判断角膜荧光素染色的区域。对主观刺激水平与角膜染色面积水平之间相关性的统计分析表明,Kanengiser评分系统(r = 0.82)比Draize评分系统(r = 0.74)具有更好的相关性。从以上数据可以看出,Kanengiser的眼部分级系统是一种有效的“确定化妆品在人眼中的眼刺激性的评估方法”。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号