In this paper the effect of the orientation of a flat heater on the heat transfer coefficient in a gas- solid fluidized bed was experimentally investigated. The effect of the rectangular heater and the gas flow was examined by changing the angle from 0 to 180, and its connection with the effect of the hydrodynamic parameters. The experimental results were conducted at ambient temperatures in a Plexiglas Coleman of 142 mm I.D. and the heater used was made of copper and electrically heated by a constant power of 6w. The heater position was at constant height in the column but its radial position was changed. Oil shale particles of different size were used as the solid phase in the fluidized bed. The velocity of air was changed in the range from 0.035 m/s to 1.8 m/s. The results obtained were discussed and compared with other previous studies. This study aids in gaining a better understanding of heat transfer mechanism which is sufficient to designing and operating the fluidized bed reactors properly.
展开▼
机译:本文通过实验研究了平板加热器的方向对气固流化床中传热系数的影响。通过将角度从0更改为180来检查矩形加热器和气流的影响,以及其与流体力学参数的影响。实验结果是在环境温度为142 mm I.D的Plexiglas Coleman上进行的。加热器由铜制成,并以6w的恒定功率进行电加热。加热器位置在色谱柱中处于恒定高度,但其径向位置已更改。在流化床中将不同尺寸的油页岩颗粒用作固相。空气速度在0.035 m / s至1.8 m / s的范围内变化。对获得的结果进行了讨论,并与其他先前的研究进行了比较。这项研究有助于更好地了解传热机理,这足以正确设计和操作流化床反应器。
展开▼