首页> 外文期刊>International journal of low carbon technologies >Entransy dissipation analysis of heat exchangers under heat leakages and varying heat capacity ratios
【24h】

Entransy dissipation analysis of heat exchangers under heat leakages and varying heat capacity ratios

机译:换热器在热泄漏和热容比变化时的全过程耗散分析

获取原文
           

摘要

The analytical work presented here aims to evaluate the entransy dissipation number in presence of heat leak with an assumption that the minimum heat capacity is on the cold fluid side. The effect of heat capacity ratio and the heat leak on the entransy dissipation number has been illustrated. Entransy dissipation number has been found out for both parallel flow heat exchanger and counter flow heat exchanger with varying Number of Transfer Units (NTU).The results portray the falloff trend of entransy dissipation with NTU for parallel flow as well as counter flow heat exchanger. A brief comparison of parallel and counter flow heat exchanger has also been depicted with a better outcome for counter flow heat exchanger.In the absence of heat leak, the mathematical model so developed for entransy dissipation number, resembles the result as presented by another researcher.
机译:此处提出的分析工作旨在评估在存在最小热容量在冷流体侧的情况下,存在热泄漏的情况下的运输损失数。已经说明了热容量比和热泄漏对传递损失数的影响。同时发现了并联换热器和逆流换热器的换热耗散数,其中换热器的数量有所不同。结果描绘了并联换热器和逆流换热器的换热耗散的下降趋势。还对并联和逆流换热器进行了简要的比较,得出了逆流换热器更好的结果。在没有热泄漏的情况下,如此开发的用于换热耗散数的数学模型类似于另一位研究者提出的结果。