2D resistivity imaging and vertical electrical sounding (VES) surveys were integrated in the study of the investigation of the level of groundwater contamination at Ile – Epo dumpsite in Agbado Oke-Odo Local Council Development Area (LCDA), Lagos State, Southwestern, Nigeria. A total of nine vertical electrical soundings and four 2D electrical imaging using Wenner configurations was used for the study. Out of these, six VES and three 2D electrical imaging were carried out on the dumpsite while three VES and one 2D imaging were carried out in a school 100m away from the dumpsite in order to serve as control. The result of interpretation of both data suggests that the study area is underlain by sand and clay formations. Results of the resistivity Imaging delineated the contaminant plume as low resistivity zones (0.5 – 48 Ωm). This was also correlated with the VES values of 0.1 to 31.6 Wm which indicate contaminant plume. This was observed to have infiltrated to a depth of about 50m which poses serious health risks to the inhabitants of that area.
机译:在尼日利亚西南部拉各斯州阿格巴多·奥克奥多地方议会开发区(LCDA)的Ile-Epo垃圾场的地下水污染水平调查研究中,集成了2D电阻率成像和垂直电测深(VES)调查。该研究总共使用Wenner配置进行了九次垂直电测深和四次2D电成像。其中,在垃圾场进行了6次VES和3次2D电子成像,而在距垃圾场100m的学校中进行了3次VES和1D 2D成像以作为控制。两种数据的解释结果表明,该研究区域位于砂和粘土地层之下。电阻率成像的结果将污染物羽流描绘为低电阻率区域(0.5 – 48Ωm)。这也与表明污染物羽流的VES值为0.1至31.6 Wm相关。据观察,该水渗入了约50m的深度,对该地区的居民构成了严重的健康风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号