首页> 外文期刊>Journal of Geology & Geophysics >Vulnerability Assessment of Groundwater to Contamination Using Electrical Resistivity Method at the Open Dumpsite in Gosa, Abuja, Nigeria
【24h】

Vulnerability Assessment of Groundwater to Contamination Using Electrical Resistivity Method at the Open Dumpsite in Gosa, Abuja, Nigeria

机译:在尼日利亚戈斯的开放式垃圾场中使用电阻率法污染地下水的脆弱性评估

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Electrical resistivity method was used to investigate the open dumpsite at Gosa, Abuja in order to determine the vulnerability of the groundwater in the area as well as the surrounding environment to leachate contamination. A total of sixteen (16) vertical electrical sounding points with maximum current electrode of 100 m were investigated. The data were analyzed and used to establish the parameters required to fulfil the objectives of this research. A maximum of four geoelectric sections were identified in the area. They included sandy topsoil, clayey sand, weathered basement and fractured/fresh basement. Apparent resistivity values obtained for the four layers delineated were between 64.6 Ωm and 215.5 Ωm for the first layer; 19.0 Ωm and 295.6 Ωm for the second layer; 66.9 Ωm and 1003.7 Ωm for the third layer; and 438.0 Ωm and 1719.9 Ωm for the fourth layer. Furthermore, the ranges of the thickness of the layers were found to be 0.7 m and 12.9 m for the first layer; 1.3 m and 9.8 m for the second layer; and 1.6 m and 11.6 m for the third layer. The depths of water table in the area were estimated to range between 2.1 and 21.6 m. The parameters used in characterizing the aquifer protective capacity of the overburden units were layer thickness and their corresponding resistivity values. Accordingly, the total longitudinal layer conductance of the overburden of the area was generally found to be low, ranging between 0.014 mhos and 0.063 mhos, implying that the aquifer protective capacity of the area is poor. The 1D resistivity cross section for the three profiles investigated exposed the movement of contaminants toward the aquifer, further validating the fact that the aquifer is not protected. The low protective capacity of the area aided the conclusion that the water aquifer in the area was highly vulnerable to leachate contamination from the dumpsite.
机译:电阻率法用于研究GOSA,阿布贾的开放式垃圾桶,以确定地区在该地区的漏洞以及周围环境渗滤污染。研究总共十六(16)个具有100米的最大电流电极的垂直电探测点。分析数据并用于建立履行本研究目标所需的参数。该地区最多鉴定了四个地质电切片。它们包括Sandy Tootsoil,Clayey Sand,风化的地下室和裂缝/新鲜地下室。对于第一层,划定的四层的表观电阻率值为64.6Ωm和215.5Ωm;第二层为19.0Ωm和295.6Ωm;第三层66.9Ωm和1003.7Ωm;第四层和438.0Ωm和1719.9Ωm。此外,对于第一层,发现层的厚度的范围为0.7μm和12.9μm;第二层1.3米和9.8米;第三层1.6米和11.6米。该区域中的水位的深度估计为2.1和21.6米的范围。用于表征覆盖层单元的含水层保护能力的参数是层厚度及其相应的电阻率值。因此,通常发现该地区的覆盖层的总纵向层电导是低,范围在0.014 MHO和0.063 MHO之间,这意味着该地区的含水层保护能力差。三种型材的1D电阻率横截面研究暴露于污染物对含水层的运动,进一步验证了含水层未受保护的事实。该地区的低保护能力促进了该地区的水含水层高度易受垃圾植物污染的侵害。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信