首页> 外文期刊>International journal of hyperthermia: The official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group >SAR deposition by curved CFMA-434 applicators for superficial hyperthermia: Measurements and simulations
【24h】

SAR deposition by curved CFMA-434 applicators for superficial hyperthermia: Measurements and simulations

机译:曲面CFMA-434敷贴器用于表面热疗的SAR沉积:测量和模拟

获取原文
       

摘要

Introduction: Contact flexible microstrip applicators (CFMA) are applied for superficial hyperthermia. In the clinic these flexible applicators are mostly applied bent along the body curvature. This paper investigates the specific absorption rate (SAR) patterns of CFMA applicators, when bent around an elliptical tissue-equivalent phantom. Methods: The 2H (aperture size 14.8 × 14.3 cmsup2/sup), 3H (28.7 × 20.7 cmsup2/sup), 4H (19.6 × 19.6 cmsup2/sup) and 5H (19.7 × 28.5 cmsup2/sup) applicators were examined. Measurements were performed for the 5H applicator; existing measurement data were analysed for the 3H applicator. Finite difference time domain (FDTD) simulations with a resolution of 2 × 2 × 1 mmsup3/sup were performed for all applicators. Applicators were bent around the top and the side of the elliptical phantom to examine different curvatures. The SAR deposition, effective field size (EFS) and effective heating depth (EHD) were evaluated and compared to results for straight applicators. Results: Bending the applicators generally yielded a focusing effect of the SAR, which was most pronounced with a strong curvature, but especially the 5H applicator showed a stronger power absorption at the sides of the applicator, compared to the centre region. The EFS became smaller when bending the applicators; this effect was also more pronounced for a strong curvature. The EHD increased for bent applicators, but the degree depended strongly on the location. Conclusion: The behaviour of bent CFMA applicators is not trivial and the SAR deposition is not similar for all applicators. The EFS decreases and the EHD increases, but very locally. Therefore, it is generally advisable to analyse the SAR distribution of flexible applicators in both straight and bent state.
机译:简介:接触式柔性微带涂药器(CFMA)用于浅表热疗。在临床中,这些柔性涂抹器大部分是沿着身体弯曲弯曲的。本文研究了当围绕椭圆组织等效体模弯曲时CFMA施加器的比吸收率(SAR)模式。方法:2H(光圈尺寸14.8×14.3 cm 2 ),3H(28.7×20.7 cm 2 ),4H(19.6×19.6 cm 2 )和5H(19.7×28.5 cm 2 )涂抹器。对5H施药器进行了测量;分析3H喷头的现有测量数据。对所有涂抹器进行了分辨率为2×2×1 mm 3 的时差有限差分(FDTD)模拟。涂药器弯曲在椭圆体模的顶部和侧面,以检查不同的曲率。评估了SAR沉积,有效场尺寸(EFS)和有效加热深度(EHD),并将其与直喷头的结果进行了比较。结果:弯曲涂药器通常会产生SAR的聚焦效果,最明显的是它具有很强的曲率,但是与中心区域相比,尤其是5H涂药器在涂药器的侧面显示出更强的能量吸收。弯曲涂药器时,EFS变小。强曲率也更明显。弯曲涂抹器的EHD有所增加,但是程度很大程度上取决于位置。结论:弯曲CFMA施加器的行为并非微不足道,并且所有沉积器的SAR沉积都不相似。 EFS降低而EHD升高,但是非常局部。因此,通常建议分析直形和弯曲状态下的柔性施药器的SAR分布。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号