A sensitive and selective electrochemical method for the determination of phenylhydrazine (PH) wasdeveloped using a modified carbon nanotube paste electrode. It has been found that under the optimumcondition (pH 5.0) in cyclic voltammetry, the oxidation of PH occurred at a potential of about 250 mVon the surface of the modified electrode. The linear range of 0.6 to 900.0 M and a detection limit of-7 1.31 10 M were observed for PH in optimum conditions. The modified electrode showed anexcellent character for electrocatalytic oxidization of PH, hydrazine (HZ) and sulfite (ST). Finally, thismethod was also examined as a selective, simple and precise electrochemical sensor for thedetermination of PH, HZ and ST in real samples such as urine and water samples.
机译:使用修饰的碳纳米管糊状电极开发了一种灵敏的选择性电化学方法,用于测定苯肼(PH)。已经发现,在循环伏安法的最佳条件(pH 5.0)下,在修饰电极的表面上以约250mV的电位发生PH的氧化。在最佳条件下,PH的线性范围为0.6至900.0 M,检测极限为-7 1.31 10M。修饰电极对PH,肼(HZ)和亚硫酸盐(ST)的电催化氧化表现出优异的特性。最后,该方法也作为选择性,简单和精确的电化学传感器进行了检测,用于测定尿液和水等真实样品中的PH,HZ和ST。