Introduction. Clotiapine is an atypical antipsychotic of the dibenzothiazepine class introduced in a few European countries since 1970, efficient in treatment-resistant schizophrenic patients. There is little published data on the therapeutic and toxic concentrations of this drug.Aims. The aim of the present study is the development and validation of a method that allows the detection and quantification of clotiapine in blood and urine specimens by gas chromatography-mass spectrometry (GC-MS).Methods. Validation was performed working on spiked postmortem blood and urine samples. Samples were extracted with liquid-liquid extraction (LLE) technique at pH 8.5 with n-hexane/dichloromethane (85/15 v/v) and analysis was followed by GC-MS. Methadone-d9 was used as internal standard.Results. The limit of detection (LOD) was 1.2 and 1.3 ng/mL for urine and blood, respectively, while the lower limit of quantification (LLOQ) was 3.9 and 4.3 ng/mL, respectively. Linearity, precision, selectivity, accuracy, and recovery were also determined. The method was applied to a postmortem case. The blood and urine clotiapine concentrations were 1.32 and 0.49 μg/mL, respectively.Conclusions. A reliable GC-MS method for the detection and quantification of clotiapine in blood and urine samples has been developed and fully validated and then applied to a postmortem case.
机译:介绍。自1970年以来,氯噻平是一种非典型的抗精神病药,二苯并噻氮平类药物在欧洲一些国家/地区推出,对治疗耐药的精神分裂症患者有效。关于这种药物的治疗和毒性浓度的公开数据很少。本研究的目的是开发和验证一种方法,该方法可以通过气相色谱-质谱(GC-MS)对血液和尿液样品中的氯丁平进行检测和定量。对加标的死后血液和尿液样本进行验证。用液-液萃取(LLE)技术在pH 8.5下用正己烷/二氯甲烷(85/15 v / v)萃取样品,然后通过GC-MS进行分析。使用美沙酮-d9作为内标。尿液和血液的检出限(LOD)分别为1.2和1.3μng/ mL,而定量下限(LLOQ)分别为3.9和4.3μng/ mL。还确定了线性,精密度,选择性,准确度和回收率。该方法适用于事后案例。血液和尿液氯硝平浓度分别为1.32和0.49μg/ mL。已经开发出一种可靠的GC-MS方法,用于检测和定量血液和尿液中的氯氮平,并已得到充分验证,然后将其应用于死后病例。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号