Cadmium (Cd) and lead (Pb) in soil or water environment cause the ecological destruction and environmental deterioration when their contents exceed the natural background values. To trace the concentrations of Cd(II) and Pb(II), a sensitive and selective electrode was developed using disposable screen-printed carbon electrode (SPE) immobilized with a composite film of reduced graphene oxide/carboxylation multi-walled carbon nanotubes/gold nanoparticle hybrid (RGO-MWNT-AuNP) through π-π bind. This highly conductive nano-composite layer, “RGO-MWNT-AuNP,” was characterized by scanning electron microscopy, UV-visible spectrometer, cyclic voltammetry, and electrochemical impedance spectroscopy. Square wave stripping voltammetry was applied to RGO-MWNT-AuNP/SPE to electroplate bismuth film and monitor the Cd(II) and Pb(II) simultaneously. To obtain high current responses, the detecting parameters were optimized. Under optimized conditions, the current responses showed a linear relationship with the concentrations of Cd(II) and Pb(II) in the range from 1.0 to 80.0 μg/L with a lower detection limit of 0.7 μg/L and 0.3 μg/L (S/N = 3), respectively. Finally, the prepared electrode was further employed to detect Cd(II) and Pb(II) in soil samples with good results.
机译:当其含量超过自然本底值时,土壤或水环境中的镉和铅会导致生态破坏和环境恶化。为了追踪Cd(II)和Pb(II)的浓度,使用固定有还原性氧化石墨烯/羧化多壁碳纳米管/金复合膜的一次性丝网印刷碳电极(SPE)开发了灵敏且选择性的电极。纳米粒子杂物(RGO-MWNT-AuNP)通过π-π结合。这种高导电性的纳米复合材料层“ RGO-MWNT-AuNP”的特征在于扫描电子显微镜,紫外可见光谱仪,循环伏安法和电化学阻抗谱。方波溶出伏安法应用于RGO-MWNT-AuNP / SPE电镀铋薄膜并同时监测Cd(II)和Pb(II)。为了获得高电流响应,优化了检测参数。在最佳条件下,电流响应与Cd(II)和Pb(II)的浓度在1.0至80.0μg/ L范围内呈线性关系,检出限较低,分别为0.7μg/ L和0.3μg/ L( S / N = 3)。最后,将制备好的电极进一步用于土壤样品中Cd(II)和Pb(II)的检测,结果良好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号