首页> 外文期刊>Indian Journal of Ophthalmology >Light exposure from microscope versus intracameral illumination during cataract surgery
【24h】

Light exposure from microscope versus intracameral illumination during cataract surgery

机译:白内障手术中显微镜照射与前房照射的关系

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Purpose: To evaluate light exposure from microscope versus intracameral illuminations to patient's and surgeon's retina during cataract surgery. Methods: Thirty consecutive patients who had cataract surgery using microscope and intracameral illuminations. At the point of the ocular of an operating microscope, optical illuminance and irradiance from the microscope illumination (60, 40, 20% intensity) and the intracameral illumination (60% intensity) were measured using a light meter and a spectrometer at a pause after lens capsule polishing in cataract surgery. Results: Average illuminance (lux) was 1.46, 0.66, 0.27, and 0.1 from 60%, 40%, 20% intensity microscope illuminations and 60% intracameral illumination. Average total spectral irradiance (μW/cm2) was 1.25, 0.65, 0.26, and 0.03 from 60%, 40%, 20% intensity microscope illuminations and 60% intracameral illumination. Conclusion: Microscope ocular illuminance and irradiance during cataract surgery were higher in the microscope illumination than in the intracameral illumination. It suggests that light exposure reaching patient's and surgeon's retina during cataract surgery is lower in the intracameral illumination than in the microscope illumination.
机译:目的:评估白内障手术期间显微镜和前房照明对患者和外科医生视网膜的曝光量。方法:连续30例使用显微镜和前房照明进行白内障手术的患者。在手术显微镜的目视点处,使用照度计和分光计在暂停后的暂停时间测量显微镜照度(60、40、20%强度)和子房内照度(60%强度)的光学照度和辐照度。白内障手术中晶状体囊的抛光。结果:从60%,40%,20%强度显微镜照度和60%前房内照度得出的平均照度(lux)为1.46、0.66、0.27和0.1。从60%,40%,20%强度的显微镜照度和60%子房内照度得出的平均总光谱辐照度(μW/ cm2)为1.25、0.65、0.26和0.03。结论:白内障手术期间的显微镜眼部照度和辐照度在显微镜照明下高于前房内照明。这表明白内障手术期间白内障手术中到达患者和外科医生视网膜的光照射比显微镜照射低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号