Aim:The aim was to evaluate visual and refractive results and complications of intraocular lens (IOL) exchange through a 3.2 mm corneal incision for opacified IOLs.Materials and Methods:This retrospective study comprised 33 eyes of 32 patients with IOL opacification requiring an IOL exchange between July 2003 and March 2007. Exchange surgery was performed through a 3.2-mm temporal clear corneal incision followed by implantation of a new foldable hydrophobic IOL. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), topographical astigmatism, and refractive cylinder were evaluated. Surgically induced astigmatism (SIA) was calculated and complications were recorded.Results:Opacification was observed in 25 eyes (76%) with Aqua-Sense, 3 eyes (9%) with Hydroview, 3 eyes (9%) with MemoryLens IOLs, and 2 eyes (6%) with DgR. The mean follow-up period was 36.54 months. An uneventful IOL exchange was achieved in 18 eyes (55%). Zonular dehiscence occurred in 9 eyes (27%), and posterior capsule tear developed in 4 eyes (12%). The mean preoperative BSCVA (mean ± standard deviation, decimal scale) was 0.13 ± 0.08 (mean: 20/150, range 20/2000 to 20/60) and improved to 0.63 ± 0.18 (mean: 20/32, range 20/60 to 20/20, P < 0.001). The mean SIA was 0.70 D. Seven eyes (21%) had 0.5 D or lower SIA.Conclusion:IOL exchange is a technically challenging procedure with potential risks of reversing the advantages of a prior small-incision cataract surgery. The use of a small corneal incision for IOL exchange could preserve the advantages of modern phacoemulsification surgery with acceptable SIA related to the procedure.
机译:目的:通过3.2 mm角膜切口评估不透明人工晶体的视觉和屈光结果以及人工晶状体(IOL)更换的并发症。材料与方法:这项回顾性研究包括32例需要人工晶体更换的IOL不透明患者的33只眼在2003年7月至2007年3月之间进行了交换手术。手术方法是通过3.2毫米的颞透明角膜切口,然后植入新的可折叠疏水性IOL。评估未矫正视力(UCVA),最佳眼镜矫正视力(BSCVA),地形像散和屈光度数。结果:手术引起的散光(SIA)并记录了并发症。结果:使用Aqua-Sense的25眼(76%),使用Hydroview的3眼(9%),使用MemoryLens IOL的3眼(9%)观察到了不透明化。 DgR 2眼(6%)。平均随访期为36.54个月。在18眼(55%)中实现了平整的IOL交换。带状裂开发生在9眼(27%),后囊撕裂发生在4眼(12%)。术前平均BSCVA(平均值±标准偏差,十进制标度)为0.13±0.08(平均值:20/150,范围20/2000至20/60)并提高至0.63±0.18(平均值:20/32,范围20/60)至20/20,P <0.001)。平均SIA为0.70D。七只眼(21%)的SIA为0.5 D或更低。结论:IOL交换是一项技术挑战性手术,可能会逆转先前小切口白内障手术的优势。使用小角膜切口进行IOL交换可以保留现代超声乳化手术的优势,并且可以接受与手术相关的SIA。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号