Radiation exposure to nuclear medicine personnel handling positron emitters from Ge-68/Ga-68 generator

机译:Ge-68 / Ga-68发生器处理正电子发射器的核医学人员的辐射暴露

获取原文

摘要

Objective:To measure the radiation exposure to nuclear medicine personnel during synthesis and injection to the patients of Ga-68 1,4,7,10-tetraazacyclododecane-N,N′,N″,N″′-tetraacetic acid (DOTA)-1-Nal3-octreotide (NOC)- (DOTA-NOC) using ring thermoluminescence dosimeters (TLDs).Materials and Methods:Synthesis of Ga-68 DOTA-NOC was done on a semi-automated system. Finger doses were measured during synthesis and injection of Ga-68 DOTA-NOC. The occupational workers wore TLDs at the base of ring finger of both hands. The finger doses of two radio chemists were measured during synthesis of Ga-68 DOTA-NOC while that of a physician during its injection to the patients.Results:Duration of the study was eight months and a total of 20 samples were prepared. During synthesis, the mean dose to base of left ring finger was 3.02 ± 1.01 mSv and to base of right ring finger was 1.96 ± 0.86 mSv. Mean dose to base of left ring finger was 1.26 ± 0.35 mSv while that to base of right ring finger was 1.03 ± 0.13 mSv during injection. The mean dose was observed to be higher during synthesis than injection. However, the difference was not significant (P = 0.27 and P = 0.18, respectively). Overall mean finger dose of left hand was 2.43 ± 1.21 mSv, whereas for the right hand the same was 1.65± 0.82 mSv.Conclusion:Finger doses to radio chemists during semi-automated synthesis of Ga-68 DOTA-NOC and that to the physician involved in injection of Ga-68 DOTA-NOC were found to be within permissible limits. Ring dosimeters must be worn for the safety of the nuclear medicine personnel involved in synthesis and injection of Ga-68 DOTA-NOC.
机译:目的:测量Ga-68 1,4,7,10-四氮杂环十二烷-N,N',N'',N'''-四乙酸(DOTA)-在合成和注射过程中对核医学人员的辐射暴露。 1-Nal3-奥曲肽(NOC)-(DOTA-NOC)使用环热发光剂量计(TLD)。材料与方法:Ga-68 DOTA-NOC的合成在半自动化系统上进行。在Ga-68 DOTA-NOC的合成和注射过程中测量手指的剂量。职业工人在两只手的无名指根部戴了顶级域名(TLD)。在合成Ga-68 DOTA-NOC的过程中测量了两名放射化学家的手指剂量,而在向患者注射时则由医生进行了测量。结果:研究时间为八个月,共制备了20个样品。在合成过程中,左手无名指的平均剂量为3.02±1.01 mSv,右手无名指的平均剂量为1.96±0.86 mSv。在注射过程中,左无名指基部的平均剂量为1.26±0.35 mSv,而右无名指基部的平均剂量为1.03±0.13 mSv。观察到在合成期间平均剂量高于注射剂量。但是,差异并不显着(分别为P = 0.27和P = 0.18)。左手的平均手指总剂量为2.43±1.21 mSv,而右手的总平均剂量为1.65±0.82 mSv。结论:Ga-68 DOTA-NOC半自动合成过程中放射化学家的手指剂量和医师的剂量发现参与Ga-68 DOTA-NOC注射的药物在允许的范围内。必须佩戴环形剂量计,以确保参与Ga-68 DOTA-NOC合成和注射的核医学人员的安全。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号