首页> 外文期刊>Imaging Science in Dentistry >A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery
【24h】

A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery

机译:一种改良的口腔放射成像设备,用于评估第三磨牙手术后下颌第二磨牙的远端骨缺损

获取原文
           

摘要

Purpose This article is to describe a modified device for intraoral radiography which was developed to obtain reproducible radiographic images for assessment of distal osseous defects of the mandibular second molar (2 Mm) after impacted third molar (3 Mm) surgery. Materials and Methods A commercial available alignment system for posterior region was modified by adding a reference gauge pin (millimetric) and threading a hollow acrylic cylinder at the ring of the radiographic positioner to attach the X-ray collimator. The design included customized resin acrylic stent for the occlusal surface of the 2Mm in maximum intercuspal position, individualizing the biteblock positioner. Periapical radiographs were taken before and after surgical extraction of 3 Mm, employing the radiographic technique of parallelism described by Kugelberg (1986) with this modified film holder and inserting the gauge pin on the deepest bone probing depth point. Results This technique permitted to obtain standardized periapical radiographs with a moderate to high resolution, repeatability, and accuracy. There was no difference between the measurements on the pre- and post-operative radiographs. This technique allowed better maintenance of the same geometric position compared with conventional one. The insertion of the gauge pin provided the same reference point and localized the deepest osseous defect on the two-dimensional radiographs. Conclusion This technique allowed better reproducibility in posterior radiographic records (distal surface of 2 Mm) and more accurate measurements of radiographic bone level by the use of a millimetric pin.
机译:目的本文介绍一种改良的口腔内放射成像设备,该设备经过开发,可获取可再现的放射线图像,以评估下颌第二磨牙(2 Mm)的第三牙(3 Mm)手术后的远端骨缺损。材料和方法通过添加参考量规针(千分尺)并在射线照相定位器的环上穿入一个空心的丙烯酸圆柱体以固定X射线准直仪,对后部区域的商用对准系统进行了修改。设计包括定制的丙烯酸丙烯酸树脂支架,用于最大maximum骨位置的2Mm咬合面,从而使咬合器定位器个性化。在手术摘除3 Mm之前和之后,使用Kugelberg(1986)描述的平行度射线照相技术,在这种改良的胶片固定器上并在最深的骨探查深度点上插入量规销,以拍摄根尖射线照片。结果该技术允许获得具有中等至高分辨率,可重复性和准确性的标准化根尖周片。术前和术后X射线照片的测量值之间没有差异。与传统技术相比,该技术可以更好地保持相同的几何位置。量规销的插入提供了相同的参考点,并在二维X射线照片上定位了最深的骨缺损。结论该技术可以在后部X线影像记录(远端2 Mm)中实现更好的重现性,并且通过使用毫米针可以更精确地测量X线影像的骨水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号