首页> 外文期刊>Indian Journal of Dental Research >A comparison between conventional and digital radiography in root canal working length determination
【24h】

A comparison between conventional and digital radiography in root canal working length determination

机译:常规和数字射线照相在根管工作长度确定中的比较

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Aim and Objectives: Obtaining a correct working length is necessary for successful root canal treatment. The aim of this study was to compare conventional and digital radiography in measuring root canal working length. Materials and Methods: In this in vitro study 20 mesio buccal canal from maxillary first molars with moderate and severe curvature and 20 canal form anterior teeth with mild curvature were chosen and their working length were measured with number 15 k file (Maillefer, DENTSPLY, Germany). Then for each canal five radiographies were taken, three conventional radiographies using three methods of processing: Manual, automatic, and monobath solution; in addition to two other digital radiographies using CCD and PSP receptors. Two independent observers measured working length in each technique. Finally, the mean of working length in each group was compared with real working length using a paired T-test. Also a one-way ANOVA test was used for comparing the two groups. The level of statistical significance was P 0.05. Results: The results have shown that there was a high interobserver agreement on the measurements of the working length in conventional and digital radiography (P≤0.001). Also there was no significant difference between conventional and digital radiography in measuring working length (P 0.05). Conclusion: Therefore it was concluded that the accuracy of digital radiography is comparable with conventional radiography in measuring working length, so considering the advantages of the digital radiography, it can be used for working length determination.
机译:目的和目标:获得正确的工作长度对于成功的根管治疗是必要的。这项研究的目的是比较常规和数字射线照相术在测量牙根管工作长度中的作用。材料和方法:在这项体外研究中,选择了中度至重度上颌第一磨牙的20条近中颊颊道和轻度曲度的20条前弯牙齿,并用15 k锉测量了其工作长度(Maillefer,DENTSPLY,德国) )。然后,对每条运河进行五次射线照相,三项常规射线照相采用三种处理方法:手动,自动和单浴解决;除了使用CCD和PSP接收器的其他两个数字射线照相。两名独立的观察员测量了每种技术的工作长度。最后,使用配对T检验将每组的平均工作长度与实际工作长度进行比较。还使用单向方差分析测试比较两组。统计学显着性水平为P <0.05。结果:结果表明,在常规和数字射线照相术中,对工作长度的测量存在很高的观察者共识(P≤0.001)。传统的和数字射线照相术在测量工作长度方面也没有显着差异(P> 0.05)。结论:因此可以得出结论,在测量工作长度时,数字射线照相的准确性可与传统射线照相相媲美,因此,考虑到数字射线照相的优点,可将其用于确定工作长度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号