首页> 外文期刊>Arquivos Brasileiros de Oftalmologia >Resultados refrativos e visuais após a inser??o do anel de Ferrara a uma profundidade de 60% em olhos com ceratocone: série de casos
【24h】

Resultados refrativos e visuais após a inser??o do anel de Ferrara a uma profundidade de 60% em olhos com ceratocone: série de casos

机译:在圆锥角膜的眼睛中插入60%深度的费拉拉环后的屈光和视觉结果:病例系列

获取原文
           

摘要

Purpose: This report addresses refractive, topographic, visual acuity, and optical coherence tomography outcomes 12 months after femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in keratoconic eyes at a depth of 60%. Methods: Interventional, prospective, non-comparative case series. We performed femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in 15 keratoconic eyes. We included patients with documented keratoconus who voluntarily signed informed consents if they had best spectacle-corrected visual acuity ≥0.30 logMAR and corneal thickness ≥400 μm. We excluded patients with previous ocular surgery or corneal curvatures 65 diopters (D). Our main outcome measures were best spectacle-corrected visual acuity and corneal topographic parameters (flattest, steepest and average keratometry [K]), evaluated at baseline and at 1-,3-,6-, and 12-month follow-ups. Results: The mean ± standard deviation baseline uncorrected visual acuity and best spectacle-corrected visual acuity were 1.03 ± 0.46 and 0.42 ± 0.13, respectively; the 12-month mean standard deviation uncorrected visual acuity and best spectacle-corrected visual acuity were 0.72 ± 0.37 and 0.31 ± 0.16, respectively, without significant differences (p=0.05 for both). The mean best spectacle-corrected visual acuity improvements were statistically significant after 3- (p=0.02) and after 6-months (p=0.02). The mean baseline flattest (K1), steepest (K2), and overall keratometries (mean power) were 48.35 ± 3.65 D, 53.67 ± 3.38 D, and 50.84 ± 3.36 D, respectively. The 12-month mean ± standard deviations for flattest-K1, steepest-K2, and overall K were 46.53 ± 3.70 D, 49.83 ± 3.50 D, and 48.12 ± 3.49 D respectively, with statistically significant differences for all three topographic parameters (p=0.01). Conclusions: Ferrara intrastromal corneal ring segment insertions at a depth of 60% yield satisfactory visual, refractive, and keratometric results in keratoconic eyes.
机译:目的:该报告探讨了飞秒激光束辅助的费拉拉基质内角膜环段在角膜圆锥角眼中的插入深度为60%后12个月后的屈光,地形,视敏度和光学相干断层扫描结果。方法:干预性,前瞻性,非比较性病例系列。我们在15个圆锥角膜上的眼睛中进行了飞秒激光辅助的Ferrara基质内角膜环段的插入。我们纳入了有圆锥形圆锥角膜的患者,如果他们的眼镜矫正视力最好≥0.30logMAR,角膜厚度≥400μm,则自愿签署知情同意书。我们排除了先前进行过眼科手术或角膜曲率大于65屈光度(D)的患者。我们的主要结局指标是在基线以及1、3、6、12个月的随访中评估的最佳眼镜矫正视力和角膜地形参数(最平,最陡和平均角膜曲率[K])。结果:基线未矫正视力的平均值±标准差和最佳眼镜矫正视力的平均值分别为1.03±0.46和0.42±0.13; 12个月的平均标准差未矫正视力和最佳眼镜矫正视力分别为0.72±0.37和0.31±0.16,无显着差异(两者均为p = 0.05)。眼镜矫正后的平均视力改善的最佳平均值在3个月后(p = 0.02)和6个月后(p = 0.02)有统计学意义。平均基线最平直度(K1),最陡峭度(K2)和总体角膜测量法(平均功效)分别为48.35±3.65 D,53.67±3.38 D和50.84±3.36D。最平坦的K1,最陡峭的K2和整体K的12个月平均±标准差分别为46.53±3.70 D,49.83±3.50 D和48.12±3.49 D,所有三个地形参数的统计差异显着(p = 0.01)。结论:费拉拉角膜内角膜环段插入深度为60%时,圆锥角膜的视觉,屈光和角膜测量结果令人满意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号