首页> 外文期刊>Annals of laboratory medicine. >Efficiency of an Automated Reception and Turnaround Time Management System for the Phlebotomy Room
【24h】

Efficiency of an Automated Reception and Turnaround Time Management System for the Phlebotomy Room

机译:采血室自动接收和周转时间管理系统的效率

获取原文
           

摘要

Background: Recent advances in laboratory information systems have largely been focused on automation. However, the phlebotomy services have not been completely automated. To address this issue, we introduced an automated reception and turnaround time (TAT) management system, for the first time in Korea, whereby the patient’s information is transmitted directly to the actual phlebotomy site and the TAT for each phlebotomy step can be monitored at a glance.Methods: The GNT5 system (Energium Co., Ltd., Korea) was installed in June 2013. The automated reception and TAT management system has been in operation since February 2014. Integration of the automated reception machine with the GNT5 allowed for direct transmission of laboratory order information to the GNT5 without involving any manual reception step. We used the mean TAT from reception to actual phlebotomy as the parameter for evaluating the efficiency of our system.Results: Mean TAT decreased from 5:45 min to 2:42 min after operationalization of the system. The mean number of patients in queue decreased from 2.9 to 1.0. Further, the number of cases taking more than five minutes from reception to phlebotomy, defined as the defect rate, decreased from 20.1% to 9.7%Conclusions: The use of automated reception and TAT management system was associated with a decrease of overall TAT and an improved workflow at the phlebotomy room.
机译:背景:实验室信息系统的最新进展主要集中在自动化方面。但是,放血服务尚未完全自动化。为了解决这个问题,我们在韩国首次引入了自动接收和周转时间(TAT)管理系统,该系统将患者的信息直接传输到实际的放血部位,并且可以在每个放血步骤监控TAT。方法:2013年6月安装了GNT5系统(韩国Energium Co.,Ltd.)。自动接收和TAT管理系统自2014年2月开始运行。将自动接收机与GNT5集成后,可以直接使用无需任何人工接收步骤即可将实验室订单信息传输到GNT5。我们使用从接收到实际放血的平均TAT作为评估系统效率的参数。结果:系统运行后,平均TAT从5:45分钟减少到2:42分钟。排队的平均人数从2.9减少到1.0。此外,从接收到放血的时间超过5分钟的病例数(定义为缺陷率)从20.1%下降到9.7%。结论:使用自动接收和TAT管理系统与总体TAT的降低,放血室的工作流程得到改善。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号