Background: We evaluated the analytical and clinical performances of the SD BIOLINE Rota/Adeno Rapid kit (SD Rota/Adeno Rapid; Standard Diagnostics, Inc., Korea), an immunochromatographic assay (ICA), for the simultaneous detection of rotaviruses and adenoviruses in human stool samples. Methods: We tested 400 clinical stool samples from patients with acute gastroenteritis and compared the ICA results with the results obtained by using ELISA, enzyme-linked fluorescent assays (ELFA), PCR, and multiplex reverse transcription-PCR (mRT-PCR). To assess the analytical performance of the SD BIOLINE Rota/Adeno Rapid kit, we determined its detection limit, reproducibility, cross-reactivity, and analytical reactivity for adenovirus subtypes, and performed interference studies. Results: The overall agreement rates among the tested methods were 91.5% for rotavirus and 85.5% for adenovirus. On the basis of mRT-PCR, the overall agreement, positive agreement, and negative agreement rates of the ICA were 95.6%, 100%, and 94.9% for rotavirus, and 94.0%, 71.4%, and 94.8% for adenovirus, respectively. Using the ICA, we detected all the subtypes of adenovirus tested, but the analytical reactivities for adenovirus subtypes were different between the 4 adenovirus detection methods. The high reproducibility was confirmed, and no cross-reactivity or interference was detected. Conclusions: The SD BIOLINE Rota/Adeno Rapid kit showed acceptable analytical and clinical performances. However, interpretation of adenovirus positiveegative result should be cautious because of different detectability for adenovirus subtypes among adenovirus detection methods.
机译:背景:我们评估了SD BIOLINE Rota / Adeno Rapid试剂盒(SD Rota / Adeno Rapid; Standard Diagnostics,Inc.,韩国)(一种免疫色谱分析(ICA))的分析和临床性能,用于同时检测轮状病毒和腺病毒。人粪便样本。方法:我们测试了400例急性胃肠炎患者的临床粪便样本,并将ICA结果与通过ELISA,酶联荧光测定(ELFA),PCR和多重逆转录PCR(mRT-PCR)获得的结果进行了比较。为了评估SD BIOLINE Rota / Adeno Rapid试剂盒的分析性能,我们确定了其对腺病毒亚型的检测限,重现性,交叉反应性和分析反应性,并进行了干扰研究。结果:轮状病毒和腺病毒的测试方法之间的总体一致性率为91.5%和85.5%。根据mRT-PCR,轮状病毒的ICA总体一致性,阳性一致性和阴性一致性率分别为95.6%,100%和94.9%,腺病毒分别为94.0%,71.4%和94.8%。使用ICA,我们检测了所有测试的腺病毒亚型,但是在4种腺病毒检测方法之间,腺病毒亚型的分析反应性不同。确认了高再现性,未检测到交叉反应或干扰。结论:SD BIOLINE Rota / Adeno Rapid试剂盒显示出可接受的分析和临床性能。但是,由于腺病毒检测方法对腺病毒亚型的可检测性不同,因此对腺病毒阳性/阴性结果的解释应谨慎。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号