首页> 外文期刊>Annals of Intensive Care >Changes in dynamic arterial elastance induced by volume expansion and vasopressor in the operating room: a prospective bicentre study
【24h】

Changes in dynamic arterial elastance induced by volume expansion and vasopressor in the operating room: a prospective bicentre study

机译:手术室中容积扩张和血管加压药诱导的动态动脉弹性变化:一项前瞻性bicentre研究

获取原文
           

摘要

Abstract BackgroundDynamic arterial elastance (Eadyn), defined as the ratio between pulse pressure variations and stroke volume variations, has been proposed to assess functional arterial load. We evaluated the evolution of Eadyn during volume expansion and the effects of neosynephrine infusion in hypotensive and preload-responsive patients.MethodsIn this prospective bicentre study, we included 56 mechanically ventilated patients in the operating room. Each patient had volume expansion and neosynephrine infusion. Stroke volume and stroke volume variations were obtained using esophageal Doppler, and pulse pressure variations were measured through the arterial line. Pressure response to volume expansion was defined as an increase in mean arterial pressure (MAP)?≥?10%.ResultsTwenty-one patients were pressure responders to volume expansion. Volume expansion induced a decrease in Eadyn (from 0.69 [0.58–0.85] to 0.59 [0.42–0.77]) related to a decrease in pulse pressure variations more pronounced than the decrease in stroke volume variations. Baseline and changes in Eadyn after volume expansion were related to age, history of arterial hypertension, net arterial compliance and effective arterial elastance. Eadyn value before volume expansion??0.65 predicted a MAP increase?≥?10% with a sensitivity of 76% (95% CI 53–92%) and a specificity of 60% (95% CI 42–76%). Neosynephrine infusion induced a decrease in Eadyn (from 0.67 [0.48–0.80] to 0.54 [0.37–0.68]) related to a decrease in pulse pressure variations more pronounced than the decrease in stroke volume variations. Baseline and changes in Eadyn after neosynephrine infusion were only related to heart rate.ConclusionEadyn is a potential sensitive marker of arterial tone changes following vasopressor infusion.
机译:摘要背景动态动脉弹性(Eadyn)被定义为脉压变化与搏动量变化之间的比率,已被提出来评估功能性动脉负荷。我们评估了降压和预负荷反应患者中Eadyn演变过程中的容量变化以及新正肾上腺素输注的影响。每例患者均进行容量扩张和新肾上腺素输注。使用食道多普勒获得搏动量和搏动量变化,并通过动脉管路测量脉压变化。对体积膨胀的压力反应定义为平均动脉压(MAP)≥10%。结果21例患者对体积膨胀产生压力反应。体积膨胀引起的Eadyn下降(从0.69 [0.58–0.85]降至0.59 [0.42–0.77])与脉搏压力变化的减小相比于冲程体积变化的减小更为明显。容量增加后,Eadyn的基线和变化与年龄,动脉高血压病史,净动脉顺应性和有效动脉弹性有关。体积膨胀前的Eadyn值≥0.65预测MAP升高≥10%,灵敏度为76%(95%CI 53-92%),特异性为60%(95%CI 42-76%)。新肾上腺素输注引起的Eadyn减少(从0.67 [0.48–0.80]降低至0.54 [0.37–0.68])与脉搏压力变化的减少相比,其搏动量变化的减少更为明显。新肾上腺素输注后Eadyn的基线和变化仅与心率有关。结论Eadyn是输注血管加压药后动脉张力变化的潜在敏感标志物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号