Evaluation of the usefulness of the immunoradiometric method for post-mortem measurement of insulin concentration in the intraocular fluid: preliminary results

机译:免疫放射法对眼内液中胰岛素浓度的验尸测量的有效性评估:初步结果

获取原文
       

摘要

Introduction In medicolegal practice, rare cases associated with suicidal, criminal or accidental overdose of insulin are both analytically and forensically challenging. The determination of insulin in post-mortem blood has limited diagnostic value, mainly on account of post-mortem chemical degradation processes (particularly hemolysis), and hence is not useful in medicolegal practice. Aim of the study The aims of the study were: 1) to assess the usefulness of the immunoradiometric method, used in clinical practice, for post-mortem measurement of insulin concentration in the intraocular fluid, 2) to preliminarily evaluate the usefulness of the obtained results for toxicological and medicolegal assessment, and 3) to verify on the basis of our own material the validity of the cited literature data on the effect of hemolysis on the result of insulin level determination in post-mortem blood. Material and methods The study material consisted of 93 samples of intraocular fluid collected during consecutive medicolegal autopsies performed in the Department of Forensic Medicine and Forensic Toxicology, Medical University of Silesia in Katowice. In addition, 10 samples of peripheral blood taken from living people (5 women and 5 men) for clinical and diagnostic purposes were analyzed. Insulin(e) IRMA KIT from IMMUNOTECH was used for the analyses. Results In 86 (92.5%) samples, the insulin concentration was below the analytical sensitivity of the method (less than 0.5 μIU/ml), while in 7 cases it was in the range of 1.42–24.42 μIU/ml. Conclusions Determination of the insulin level in the intraocular fluid by the immunoradiometric method provides an opportunity for objective verification of poisoning, however this claim requires further research.
机译:简介在法医学实践中,与自杀,刑事或意外用药过量有关的罕见病例在分析和法医上均具有挑战性。死后血液中胰岛素的测定具有有限的诊断价值,主要是由于死后化学降解过程(尤其是溶血),因此在法医学实践中没有用。研究的目的该研究的目的是:1)评估免疫放射法在临床实践中用于眼内液中胰岛素浓度的事后测量的有效性,2)初步评估所获得的方法的有效性。进行毒理学和法医学评估的结果,以及3)在我们自己的材料基础上验证引用的文献数据对溶血对验血后胰岛素水平测定结果的影响的有效性。材料和方法研究材料由在卡托维兹西里西亚医科大学法医学和法医学毒理学系进行的连续法医学尸体解剖期间收集的93眼内液样本组成。另外,分析了从活人(5名女性和5名男性)中提取的10份用于临床和诊断目的的外周血样本。使用IMMUNOTECH的IRMA KIT胰岛素进行分析。结果在86个样本中(92.5%),胰岛素浓度低于该方法的分析灵敏度(小于0.5μIU/ ml),而在7个病例中,其胰岛素浓度在1.42–24.42μIU/ ml范围内。结论通过免疫放射法测定眼内液中的胰岛素水平为客观验证中毒提供了机会,但是这一说法尚需进一步研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号