...
首页> 外文期刊>Applied bionics and biomechanics >Recent Observations in Surface Electromyography Recording of Triceps Brachii Muscle in Patients and Athletes
【24h】

Recent Observations in Surface Electromyography Recording of Triceps Brachii Muscle in Patients and Athletes

机译:运动员和运动员肱三头肌肌肉表面肌电图记录的最新观察

获取原文
           

摘要

Objective: To observe and analyse the literature on the use of surface electromyography electrodes, including the shape, size, and metal composition of the electrodes used, the interelectrode distance, and the anatomical locations on the muscle at which the electrodes are placed, for the observation of the triceps brachii muscle activity in patients and athletes.Methods: We searched the ScienceDirect and SpringerLink online databases for articles published in the English language during the last six years (between January 2008 and December 2013). We specifically searched for the keywords “EMG” and “triceps brachii” in the full text of each of the articles. The inclusion criteria were articles on the use of surface electromyography electrodes to observe the activity of the triceps brachii muscle in patients and athletes.Results: In the 23 selected articles, the activities of the triceps brachii muscle in a total of 402 subjects were measured using surface electromyography electrodes: 262 subjects in the studies that focused on the rehabilitation of patients with various disorders, and 140 subjects in the studies that focused on the sports performance of various athletes. To record the surface electromyography activity of the triceps brachii muscle, the electrodes were placed over the muscle belly or the three heads (lateral, long, and medial) of the triceps brachii muscle with diverse interelectrode distances. Seventeen studies used bipolar or triode silver/silver chloride electrodes, one study utilised bipolar gold electrodes, one study applied bipolar polycarbonate electrodes, one study used a linear array of four silver bar electrodes, one study utilised DELSYS parallel bar nickel silver electrodes, and two studies did not clearly mention the composition of the electrodes used.Conclusions: Bipolar silver/silver chloride circular-shaped electrodes are utilised more frequently than electrodes with a different metal composition and shape. The anatomical locations of the triceps brachii muscle that mainly considered for electrode placement are the lateral, long, and medial heads. A 10-mm electrode size is commonly used to measure the sEMG activity more efficiently. However, we found that an electrode size of up to 40 mm may be used to reliably measure the sEMG activity on the triceps brachii muscle. A 20-mm interelectrode distance is commonly used to measure the sEMG activity using the above mentioned muscle locations and silver/silver chloride electrodes. We also identified others factors that should be taken into account for the use of the sEMG recording technique on the triceps brachii under real-time conditions.
机译:目的:观察和分析有关使用表面肌电图电极的文献,包括使用的表面肌电图电极的形状,大小和金属成分,电极间距离以及电极在肌肉上的解剖位置。方法:我们搜索了过去六年(2008年1月至2013年12月)以英语发表的文章,并在ScienceDirect和SpringerLink在线数据库中进行了搜索。我们在每篇文章的全文中专门搜索了关键词“ EMG”和“肱三头肌”。纳入标准为关于使用表面肌电图电极观察患者和运动员肱三头肌肌肉活动的文章。结果:在选择的23篇文章中,共测量了402名受试者的肱三头肌肌肉活动。表面肌电图电极:研究中有262名受试者专注于各种疾病患者的康复,研究中有140名受试者专注于各种运动员的运动表现。为了记录肱三头肌的表面肌电图活性,将电极放置在肱三头肌的肌肉腹部或三个头(外侧,长和内侧)上,电极间的距离不同。十七项研究使用了双极或三极银/氯化银电极,一项研究使用了双极金电极,一项研究使用了双极聚碳酸酯电极,一项研究使用了四个银条电极的线性阵列,一项研究使用了DELSYS平行条状镍银电极,还有两项研究研究并未明确提及所用电极的成分。结论:双极型银/氯化银圆形电极比具有不同金属成分和形状的电极使用频率更高。主要考虑电极放置的肱三头肌肱三头肌的解剖位置是外侧头,长头和内侧头。通常使用10毫米的电极尺寸来更有效地测量sEMG活性。但是,我们发现最大40 mm的电极尺寸可以用来可靠地测量肱三头肌上的sEMG活性。通常使用20毫米的电极间距离来测量sEMG活性,使用上述肌肉位置和银/氯化银电极。我们还确定了在实时条件下在肱三头肌上使用sEMG记录技术应考虑的其他因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号