首页> 外文期刊>Analytical Sciences >The Use of 3-(2-Pyridyl)-5,6-diphenyl-1,2,4-triazine as a Precolumn Derivatizing Reagent in HPLC Determination for Fe(II) in Natural Samples
【24h】

The Use of 3-(2-Pyridyl)-5,6-diphenyl-1,2,4-triazine as a Precolumn Derivatizing Reagent in HPLC Determination for Fe(II) in Natural Samples

机译:3-(2-吡啶基)-5,6-二苯基-1,2,4-三嗪作为柱前衍生试剂在高效液相色谱法测定天然样品中铁(II)中的应用

获取原文
           

摘要

3-(2-Pyridyl)-5,6-diphenyl-1,2,4-triazine (PDT) was used for the first time as a precolumn derivatizing reagent in the high-performance liquid chromatography (HPLC) method with UV absorbance detection for the Fe(II) determination. The Fe(II) reacts with PDT to form a magenta colored chelate in the presence of sodium dodecyl sulfate (SDS) and acetic acid-sodium acetate buffer solution medium of pH 4.65. The selection of maximum absorbance detection wavelength and the optimum composition of the organic modifier in the mobile phase were investigated in detail for the quantitative determination of Fe(II) using HPLC system. The formed Fe(II)-PDT chelate was satisfactorily separated from PDT on an Agilent Shim-pack ODS column (Eclipse XDB-C8, 4.6 × 150 mm) by isocratic elution with acetonitrile and 0.02 mol L-1 acetic acid-sodium acetate buffer solution (pH 4.65, containing 0.02% of SDS and 60 × 10-3 mol L-1 NaClO4) as mobile phase at a flow rate of 1 mL min-1, and monitored with a multiple wavelength detector. The detection limit (S/N = 3) is 0.35 ng mL-1. Due to the excellent separation ability of HPLC, the innovative introduction of PDT as the precolumn derivatizing reagent, and the proper selection of the detect wavelength, the sensitivity of our newly developed HPLC method was enhanced remarkably compared to those of the common spectrophotometric methods. The developed HPLC method was successfully applied to the determination of Fe(II) in lake water samples.
机译:3-(2-吡啶基)-5,6-二苯基-1,2,4-三嗪(PDT)首次用作具有UV吸收检测功能的高效液相色谱(HPLC)方法中的柱前衍生试剂用于Fe(II)的测定。 Fe(II)与PDT在十二烷基硫酸钠(SDS)和pH值为4.65的乙酸-乙酸钠缓冲溶液介质存在下反应,形成品红色螯合物。详细研究了最大吸收检测波长的选择和流动相中有机改性剂的最佳组成,以使用HPLC系统定量测定Fe(II)。通过乙腈和0.02 mol L-1乙酸-乙酸钠缓冲液等度洗脱,将形成的Fe(II)-PDT螯合物在安捷伦Shim-pack ODS色谱柱(Eclipse XDB-C8,4.6×150 mm)上与PDT令人满意地分离。溶液(pH 4.65,包含0.02%的SDS和60×10-3 mol L-1 NaClO4)作为流动相,流速为1 mL min-1,并使用多波长检测器进行监测。检出限(S / N = 3)为0.35 ng mL-1。由于HPLC的优异分离能力,创新的引入PDT的作为预柱衍生试剂,和检测波长的适当选择,我们的新开发的HPLC方法的灵敏度得到显着增强相比,这些共同的分光光度方法。所开发的HPLC方法已成功地用于测定湖水样品中的Fe(II)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号