A flow injection method has been developed for the determination of lead in steel samples by coupling on-line preconcentration on a lead selective resin, Pb·Spec™, with flame atomic absorption spectrometry. The sample prepared as a nitric acid solution is passed through a column packed with Pb·Spec™. The lead retained on the column is then eluted with ammonium oxalate solution and introduced directly into the nebulizer of a flame atomic absorption spectrophotometer. The proposed method was successfully applied to the determination of lead in pure iron certified reference material [0.19 ± 0.01 ppm (n=6); certified value: 0.2 ppm] and lead-free cutting steel certified reference material [0.0952 ± 0.0008% (n=3); certified value: 0.097%]. The detection limit (3σ) was 0.05µg of lead.
机译:通过将铅选择性树脂Pb·Spec™上的在线预浓缩与火焰原子吸收光谱法结合使用,已经开发了一种流动注射方法来测定钢样品中的铅。将制成硝酸溶液的样品通过装有Pb·Spec™的色谱柱。然后用草酸铵溶液洗脱保留在柱上的铅,并将其直接引入火焰原子吸收分光光度计的雾化器中。所提出的方法已成功地用于测定纯铁认证标准物质中的铅[0.19±0.01 ppm(n = 6);认证值:0.2 ppm]和无铅切割钢认证参考材料[0.0952±0.0008%(n = 3);认证值:0.097%]。检出限(3σ)为0.05µg铅。