Methods for the determination of boron in various matrices described in the literature usually employ complexing agents like mannitol to retain the volatile boron species during matrix evaporation steps. However, also relatively high boron recoveries from silicon containing samples have been reported when no complexing agents were added to the digestion acids. The mechanism behind this matrix-dependant recovery has been investigated by studying the boron recovery in the analysis of solar grade silicon. It was found that the NH4+ ion formed by the reduction of nitric acid during sample digestion is responsible for the higher recovery of boron, which leads to a possible analysis method without the use of complexing agents if the sample preparation procedure is carefully optimized.
机译:文献中描述的用于测定各种基质中硼的方法通常使用络合剂(如甘露醇)在基质蒸发步骤中保留挥发性硼物质。但是,当没有将络合剂添加到消化酸中时,据报道含硅样品中的硼回收率也相对较高。通过研究太阳能级硅分析中的硼回收率,已经研究了这种依赖于基质的回收率的机理。结果发现,样品消解过程中硝酸还原形成的NH4 +离子可提高硼的回收率,如果精心优化了样品制备过程,则无需使用络合剂即可提供一种可能的分析方法。