首页> 外文期刊>Analytical methods >Assessment of arsenic, chromium, copper and manganese determination in thermal spring waters by electrothermal atomic absorption spectrometry using various chemical modifiers
【24h】

Assessment of arsenic, chromium, copper and manganese determination in thermal spring waters by electrothermal atomic absorption spectrometry using various chemical modifiers

机译:使用各种化学改性剂的电热原子吸收光谱法评估温泉水中的砷,铬,铜和锰含量

获取原文
           

摘要

Determination of total arsenic, chromium, copper and manganese in hot spring waters containing highly complex matrices and interferences by electrothermal atomic absorption spectrometry (ETAAS) was carried out in the presence of Ni, Pd, Ni + Pd and Ni + Pd + citric acid (CA) as chemical modifiers. Pyrolysis and atomization temperatures of analytes in sample and aqueous standard solutions, atomization and background profiles of analytes in sample solutions were obtained with and without modifiers and compared with each other. Effects of mass and mass ratio of modifiers were also studied. Limit of detection (LOD), limit of quantification (LOQ) and characteristic masses (mo) of analytes were found in the presence and absence of modifiers. Among the tested modifier mixtures, the Ni + Pd + CA modifier mixture was found to be preferable for the determination of analytes. The lowest LOD and mo values obtained with Ni + Pd + CA were 0.8 ??g La?’1 and 32 pg for As, 0.5 ??g La?’1 and 5.0 pg for Cr, 0.6 ??g La?’1 and 18 pg for Cu and 0.4 ??g La?’1 and 4 pg for Mn, respectively. The percent relative error found was below 5% for the determination of the analytes by the proposed method in the certified reference materials (CRMs) of water (Spsww-1 and 1643e). Arsenic in CRMs and sample solutions was also determined by hydride generation atomic absorption spectrometry (HGAAS) for the purpose of comparing with As results obtained by ETAAS. Results of analytes in sample solutions were compared with national and international water quality guidelines such as WHO and US EPA values, as well as literature data.
机译:在镍,钯,镍+钯和镍+钯+柠檬酸( CA)作为化学改性剂。在有或没有改性剂的情况下,获得样品和标准水溶液中分析物的热解和雾化温度,样品溶液中分析物的雾化和本底图,并将它们进行比较。还研究了改性剂的质量和质量比的影响。在存在和不存在修饰剂的情况下,发现分析物的检出限(LOD),定量限(LOQ)和特征质量(mo)。在测试的改性剂混合物中,发现Ni + Pd + CA改性剂混合物对于分析物的测定是优选的。用Ni + Pd + CA获得的最低LOD和mo值分别为0.8ΔgLa?'1和32 pg(砷),0.5ΔgLa?'1和Cr(5.0 pg),0.6ΔgLa?'1 Cu分别为18 pg和Mn为0.4 pg gLaδ'1,Mn为4 pg。通过拟议的方法在水的认证参考材料(CRM)(Spsww-1和1643e)中测定分析物时,发现相对误差百分比低于5%。还通过氢化物发生原子吸收光谱法(HGAAS)测定了CRM和样品溶液中的砷,以便与ETAAS获得的As结果进行比较。将样品溶液中分析物的结果与国家和国际水质指南(例如WHO和US EPA值)以及文献数据进行了比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号