Simultaneous Direct Determinations of Na, Mg, K, Ca, P, and S in Biodiesel Fuel by ICP-QMS/QMS after Xylene Dilution: Development and Application of a High-throughput Method for a Homogeneity Assessment of a Candidate Reference Material

机译:二甲苯稀释后通过ICP-MS / QMS同时直接测定生物柴油中的Na,Mg,K,Ca,P和S:候选标准物质均质性评估的高通量方法的开发和应用

获取原文

摘要

Inductively coupled plasma tandem quadrupole mass spectrometry (ICP-QMS/QMS) measurements after xylene dilution were investigated as a method for determining the elements (Na, Mg, K, Ca, P, and S) in a biodiesel fuel (BDF) candidate reference material (RM). Optimizations were respectively carried out for the following parameters to obtain the best performance for measurements: O2 flow rate (additional gas to the carrier gas) to ensure complete combustion of the xylene solvent in the plasma, plasma power to obtain lower background signal intensities for Na and K, O2 flow rate (reaction cell gas) to remove any spectral interference with the S, H2 flow rate so as to remove spectral interference with Ca. After optimization, the lower detection limits of Na, Mg, K, Ca, P, and S were 0.0004, 0.00004, 0.0003, 0.00012, 0.00005, and 0.002 mg kg?1, respectively. Typical relative standard deviations were 2.1, 2.0, 1.7, 1.1, 2.5, and 2.5% for Na, Mg, K, Ca, P, and S, respectively, where the elemental concentrations in the BDF sample were, respectively, ca. 1 mg kg?1 each for Na, Mg, K and Ca, ca. 2 mg kg?1 for P, and ca. 6 mg kg?1 for S. The established method was applied to the homogeneity assessment of a candidate RM of BDF made from palm oil. The relative uncertainties of the homogeneity were 0.3, 0.4, 0.6, 0.3, 1.6, and 0.6% for Na, Mg, K, Ca, P, and S, respectively.
机译:研究了二甲苯稀释后的电感耦合等离子体串联四极杆质谱(ICP-QMS / QMS)测量方法,作为确定生物柴油燃料(BDF)候选参考中元素(Na,Mg,K,Ca,P和S)的方法材料(RM)。分别对以下参数进行了优化,以获得最佳的测量性能:O2流速(载气中的附加气体)以确保二甲苯溶剂在等离子体中完全燃烧,等离子体功率获得Na的较低背景信号强度和K,O2流量(反应池气体)以消除与S,H2流量的任何光谱干扰,从而消除与Ca的光谱干扰。优化后,Na,Mg,K,Ca,P和S的最低检出限分别为0.0004、0.0004、0.0003、0.00012、0.00005和0.002 mg kg?1。 Na,Mg,K,Ca,P和S的典型相对标准偏差分别为2.1%,2.0%,1.7%,1.1%,2.5%和2.5%,而BDF样品中的元素浓度分别为ca. Na,Mg,K和Ca分别约为1 mg kg?1。 P为2 mg kg?1,约。 S为6 mg kg?1。已建立的方法用于评估棕榈油制成的BDF候选RM的均质性。 Na,Mg,K,Ca,P和S的均一性的相对不确定度分别为0.3%,0.4%,0.6%,0.3%,1.6%和0.6%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号