首页> 外文期刊>Analytical Sciences >Molybdenum Blue Spectrophotometry for Trace Arsenic in Ground Water Using a Soluble Membrane Filter and Calcium Carbonate Column
【24h】

Molybdenum Blue Spectrophotometry for Trace Arsenic in Ground Water Using a Soluble Membrane Filter and Calcium Carbonate Column

机译:可溶性膜过滤器和碳酸钙色谱柱用于钼蓝分光光度法测定地下水中的痕量砷

获取原文
       

摘要

An improved molybdenum blue spectrophotometry using a soluble membrane filter and CaCO3-column was proposed for determining arsenic in drinking water supplied from ground water in the presence of phosphate. A 100 mL sample solution containing 0.5 – 10 μg arsenic was passed through a CaCO3-column to remove phosphate, arsenate (As(V)). Arsenite (As(III)) which was not retained on the column was oxidized to As(V). As(V) was converted into a heteropolymolybdenum blue anion. The blue anion was collected on a membrane filter as an ion-associate with n-dodecyltrimethylammonium ion by filtration. The filter was dissolved in 2 mL of 2-methoxyethanol. The absorbance of the solution was measured at 810 nm against a reagent blank. Total inorganic arsenic was determined by reducing As(V) to As(III) before the column treatment. The RSDs for 10 μg L−1 of As(III) and As(V) were 2.9%. Phosphate 0.2 mg L−1 (as P) and iron 0.1 mg L−1 did not interfere with the determination of 10 μg L−1 arsenic. The proposed method was successfully applied to ground waters.
机译:有人提出了一种使用可溶性膜滤器和CaCO3柱的改进的钼蓝分光光度法,用于测定在磷酸盐存在下从地下水供应的饮用水中的砷。将100 mL包含0.5 – 10μg砷的样品溶液通过CaCO3柱,以去除砷酸磷酸盐(As(V))。未保留在色谱柱上的亚砷酸盐(As(III))被氧化为As(V)。 As(V)转化为杂多钼蓝阴离子。通过过滤将蓝色阴离子与正十二烷基三甲基铵离子以离子缔合形式收集在膜滤器上。将过滤器溶解在2mL的2-甲氧基乙醇中。相对于试剂空白在810nm处测量溶液的吸光度。通过在柱处理前将As(V)还原为As(III)来测定总无机砷。 As(III)和As(V)的10μgL-1的RSD为2.9%。磷酸盐0.2 mg L-1(以P计)和铁0.1 mg L-1不干扰10μgL-1砷的测定。所提出的方法已成功地应用于地下水。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有