首页> 外文期刊>Analytical methods >Quantitative analysis and stability of the rodenticide TETS (tetramine) in finished tap water
【24h】

Quantitative analysis and stability of the rodenticide TETS (tetramine) in finished tap water

机译:自来水中杀鼠剂TETS(四胺)的定量分析和稳定性

获取原文
           

摘要

The determination of the rodenticide tetramethylenedisulfotetramine (TETS) in drinking water is reportable through the use of automated sample preparation via solid phase extraction and detection using isotope dilution gas chromatography-mass spectrometry. The method was characterized over twenty-two analytical batches with quality control samples. Accuracies for low and high concentration quality control pools were 100 and 101%, respectively. The minimum reporting level (MRL) for TETS in this method is 0.50 ??g La?’1. Five drinking waters representing a range of water quality parameters and disinfection practices were fortified with TETS at ten times the MRL and analyzed over a 28 day period to determine the stability of TETS in these waters. The amount of TETS measured in these samples averaged 100 ?± 6% of the amount fortified suggesting that tap water samples may be held for up to 28 days prior to analysis.
机译:据报道,饮用水中杀鼠剂四亚甲基二磺基四胺(TETS)的测定可通过固相萃取和同位素稀释气相色谱-质谱法进行自动样品制备来进行。该方法在22个分析批次中进行了质量控制样品的表征。低浓度和高浓度质量控制池的准确度分别为100%和101%。此方法中TETS的最小报告级别(MRL)为0.50 ?? g La?’1。用代表最大残留限量十倍的TETS强化了代表一系列水质参数和消毒实践的五种饮用水,并在28天的时间内进行了分析以确定TETS在这些水中的稳定性。这些样品中测得的TETS量平均为强化量的100±±6%,这表明自来水样品在分析前最多可保存28天。