Allergy testing is important for evidence-based care and treatment. In this paper, we report a new clinical laboratory instrument, AdvanSure AlloStation Smart, which is used for a multiple allergen-specific immunoglobulin (IgE) assay. For efficient automation of immunoblot procedures, a novel tilting carousel technology was incorporated. The analyzer showed 100.5a€“101.7% of pipetting accuracy, no sample carryover, and 0.2a€“3.2% coefficient of variation of optical precision. Assay performance on the system was comparable with that of a single allergen test, ImmunoCAP for 23 allergens. The slope and the intercept of this comparison were 0.994 and 0.070, respectively. The Pearson correlation coefficient between two methods was r = 0.836. The coefficient of variation of intra-assay precision ranged from 3.2% to 11.1% and that of inter-assay precision varied from 4.0% to 17.6%. The AdvanSure AlloStation Smart provides a simple and reliable multiple assay platform to monitor allergen-specific IgE profiles.
机译:过敏测试对于循证护理和治疗很重要。在本文中,我们报告了一种新的临床实验室仪器AdvanSure AlloStation Smart,可用于多种变应原特异性免疫球蛋白(IgE)分析。为了有效地实现免疫印迹程序的自动化,采用了一种新型的倾斜转盘技术。分析仪显示移液精度为100.5a±101.7%,无样品残留,光学精度变化系数为0.2a±3.2%。该系统的测定性能与单一过敏原测试(ImmunoCAP)对23种过敏原的测试性能相当。此比较的斜率和截距分别为0.994和0.070。两种方法之间的皮尔逊相关系数为r = 0.836。批内精密度的变异系数为3.2%至11.1%,批间精密度的变异系数为4.0%至17.6%。 AdvanSure AlloStation Smart提供了一个简单而可靠的多重测定平台,以监控特定于过敏原的IgE谱。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号