This paper proposes a useful and modern solution for monitoring temperatures and specific losses of crimped connections using a virtual instrument developed in LabVIEW. It is a flexible instrument, which allows user to measure and record values during electrical tests and compare them with references, in order to decide if the tests should continue or not. The proposed solution is very useful not only for the steady state thermal regime but also for transient regime because it can be identified the improper connections before the final electrical machine or equipment assembly. The determination of specific losses implies calculating the initial rate of temperature raise starting from steady state thermal regime equation. A good crimped connection can withstand high levels of temperature and vibration, and it is of paramount importance to detect any failure before final assembly. Therefore, there are two main advantages of using this proposed solution. Firstly, it is a less time-consuming solution for electrical tests in order to detect any improper connections which could affect the electrical machine further operation. Secondly, it is very useful in order to identify those crimped connections that have not been executed correctly before final assembly. In the final part of the paper it was concluded that it will be of significant importance to develop further this virtual instrument in order to provide the user with the possibility of having a graphical representation of the acquired and stored data in real time. It is the case of temperature recorded during electrical tests.
机译:本文提出了一种有用的现代解决方案,使用在LabVIEW中开发的虚拟仪器监控温度和压接连接的特定损耗。它是一种灵活的仪器,允许用户在电气测试过程中测量和记录值,并将其与参考值进行比较,以便确定测试是否应该继续。所提出的解决方案不仅对于稳态热状态而且对于瞬态状态都是非常有用的,因为可以在最终的电机或设备组装之前识别出不正确的连接。确定特定损耗意味着从稳态热态方程开始计算初始升温速率。良好的压接连接可以承受高水平的温度和振动,并且在最终组装之前检测任何故障至关重要。因此,使用此建议解决方案有两个主要优点。首先,它是用于电气测试的耗时较少的解决方案,以检测可能影响电机进一步运行的任何不正确的连接。其次,这对于在最终组装之前识别出未正确执行的压接连接非常有用。在本文的最后部分,得出的结论是,进一步开发此虚拟仪器对于为用户提供实时获取和存储数据的图形表示的可能性将具有重要意义。在电气测试期间记录温度的情况。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号