首页> 外文期刊>American Journal of Engineering Research >Voltage Stability Investigation of the Nigeria 330KV Interconnected Grid System Using Eigenvalues Method
【24h】

Voltage Stability Investigation of the Nigeria 330KV Interconnected Grid System Using Eigenvalues Method

机译:特征值法研究尼日利亚330KV互联电网的电压稳定性

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Voltage stability investigation of the Nigeria 330kV grid Power Network was carried out using Eigenvalues method. The power system Jacobian matrix was derived using Newton -Raphson power flow solution iterative method to determine the eigenvalues for the voltage stability evaluation of both the existing 28-bus and improved 52 -bus Nigeria 330kV power networks. Positive and negative eigenvalues quantifying the power system vo ltage stability were identified. For a steady state power system, positive and negative eigenvalues showed stable and unstable systems respectively. The eigenvalues voltage stability method was developed, formulated and implemented on the existing 28-bus and proposed improved 52 -bus Nigeria 330kV power networks. The various eigenvalues, eigenvectors, participation factors and weak buses contributing to system voltage instability were determined using Matlab/SIMULINK Power System Analysis Toolbox (PSAT) for these power networks.
机译:使用特征值方法对尼日利亚330kV电网进行了电压稳定性研究。使用牛顿-拉夫森潮流解决方案迭代法推导了电力系统雅可比矩阵,以确定本征值,以评估现有的28母线和改进的52母线尼日利亚330kV电网的电压稳定性。确定了量化电力系统电压稳定性的正负特征值。对于稳态电力系统,正和负特征值分别显示稳定和不稳定的系统。本征值电压稳定方法是在现有的28总线上开发,制定和实施的,并提出了改进的52总线尼日利亚330kV电网。使用Matlab / SIMULINK电力系统分析工具箱(PSAT)确定了这些电力网络的各种特征值,特征向量,参与因子和弱母线,这些电压会导致系统电压不稳定。