...
首页> 外文期刊>American Journal of Analytical Chemistry >A Comparative Study of Non-Volatile Compounds Present in 3R4F Cigarettes and iQOS Heatsticks Utilizing GC-MS
【24h】

A Comparative Study of Non-Volatile Compounds Present in 3R4F Cigarettes and iQOS Heatsticks Utilizing GC-MS

机译:利用GC-MS对3R4F香烟和iQOS加热棒中存在的挥发性化合物进行比较研究

获取原文
           

摘要

It is now widely suggested that people who are dependent on nicotine should switch from ordinary tobacco smoking to alternative products, which at least reduce the overall harm from smoking. A number of alternatives are now popular, including electronic cigarettes and heatsticks. In this work comparative analysis of the smoke/aerosol emission from 3R4F standard cigarettes and iQOS heatsticks was undertaken. For this, gas chromatography-mass spectrometry (GC-MS) analysis was applied, to measure the non-volatile compounds of smoke/aerosol emission from individual samples, with the specific aim to determine their content of nicotine and selected other main components. All measurement data were collected under the Health Canada Intense (HCI) puffing regime. The most relevant findings of the present investigation can be summarized as follows. First, the number of measured aerosol components in the iQOS samples, with respect to those of 3R4F samples, was significantly lower (notably 37 versus 12 components). Second, the analysis of the iQOS and 3R4F GC-MS chromatographic fingerprints indicated a non-nicotine global component reduction (number and areas excluding nicotine) of larger than 80% for the iQOS samples in comparison to 3R4F samples. Third, the nicotine content of the iQOS aerosol was less than half that contained in the 3R4F smoke. The results from the present investigation indicate that—except for nicotine—smokers are exposed to a largely reduced number and amount of non-volatile, non-nicotine components in the iQOS heatstick aerosol, in comparison to those in the 3R4F cigarette smoke.
机译:现在,广泛建议依赖尼古丁的人应从普通吸烟转向替代产品,这至少可以减少吸烟的总体危害。现在有许多替代方法,包括电子烟​​和加热棒。在这项工作中,对3R4F标准卷烟和iQOS加热棒的烟雾排放进行了比较分析。为此,应用了气相色谱-质谱(GC-MS)分析来测量单个样品中烟气/气溶胶排放的非挥发性化合物,其具体目的是确定其烟碱和所选其他主要成分的含量。所有测量数据都是在加拿大卫生部(HCI)抽气制度下收集的。本研究最相关的发现可以总结如下。首先,相对于3R4F样品,iQOS样品中测得的气溶胶成分数量明显减少(值得注意的是37种成分对比12种成分)。其次,对iQOS和3R4F GC-MS色谱指纹图谱的分析表明,与3R4F样品相比,iQOS样品的非尼古丁全局组分减少量(除尼古丁以外的数量和面积)大于80%。第三,iQOS气雾剂中尼古丁含量少于3R4F烟雾中烟碱含量的一半。本研究的结果表明,与3R4F香烟烟雾相比,除尼古丁外,烟雾在iQOS加热棒气雾剂中暴露的数量和数量都大大减少,且数量不挥发,非尼古丁。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号