首页> 外文期刊>Advances in Analytical Chemistry >Determination of Iron Content in Different Hemoglobin Samples from Some Patients by UV-Visible Spectrophotometer
【24h】

Determination of Iron Content in Different Hemoglobin Samples from Some Patients by UV-Visible Spectrophotometer

机译:紫外可见分光光度计测定某些患者血红蛋白样品中的铁含量

获取原文

摘要

A validated, simple, accurate and precise spectrophotometric method has been proposed for the determination of iron in hemoglobin in human blood. The method is based on the reaction of iron with ammonium thiocyanate after the wet digestion of the blood samples with HNO3 and H2O2. The optimum experimental conditions have been studied carefully. The absorption maxima was occurred at 475 nm and molar absorptivity of 0.03602 L mol-1cm-1. The linear regression line was obtained in the range of 0.5 - 60 μg/mL for iron content in hemoglobin. The detection limit and the limit of quantification were found to be 0.0583 and 0.1768 μg/mL respectively for the iron, and with R2 value of 0.998. And recovery in range of 98.42 - 99.72%. Effects of pH, temperature, standing time and thiocyanate concentration on the determination of iron in human hemoglobin have been examined.
机译:已经提出了一种经过验证的,简单,准确和精确的分光光度法测定人血中血红蛋白中的铁。该方法基于血液样本中的HNO 3 和H 2 O 2 湿消化后铁与硫氰酸铵的反应。最佳实验条件已经过仔细研究。最大吸收发生在475 nm,摩尔吸收率为0.03602 L mol -1 cm -1 。对于血红蛋白中的铁含量,线性回归线的范围为0.5-60μg/ mL。铁的检出限和定量限分别为0.0583和0.1768μg/ mL,R 2 值为0.998。并且回收率在98.42-99.72%之间。研究了pH,温度,停留时间和硫氰酸盐浓度对测定人血红蛋白中铁的影响。