摘要

In the present study, an experimental investigation is performed to obtain two-dimensional velocity field of the turbulent flow through the double bend pipe outlet. The main objective of the study is to investigate the velocity fluctuation in the recirculating flow region on the double bend pipe layout. Phased Array Ultrasonic Velocity Profiler is applied to obtain two-dimensional velocity field in a turbulent flow condition. In a water circulation piping system, the experiments are conducted in the turbulent flow condition, Reynolds number Re = 10,000. The measurement positions are located x/D = 1 and 1.5 (D = 50 mm) downstream of the double bent pipe outlet. Two-dimensional velocity field from the measurement result of Phased Array is compared with Particle Image Velocity (PIV) method. The reattachment point of the recirculating flow is found at the position x/D = 1. The axial and radial velocity fluctuations are analyzed near the reattachment point. The flow distortion and flow-accelerated phenomenon occur at the measurement positions downstream of the double bend pipe outlet.
机译:在本研究中,进行了一项实验研究以获得通过双弯管出口的湍流的二维速度场。该研究的主要目的是研究双弯管布置上的再循环流区域中的速度波动。应用相控阵超声速度剖面仪在湍流条件下获得二维速度场。在水循环管道系统中,实验在湍流条件下进行,雷诺数Re = 10,000。测量位置位于双弯管出口下游的x / i = 1和1.5(d = 50 mm)。将相控阵测量结果中的二维速度场与粒子图像速度(PIV)方法进行了比较。循环流的重新连接点位于x / D = 1的位置。在重新连接点附近分析了轴向和径向速度波动。在双弯管出口下游的测量位置处发生流动变形和流动加速现象。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号