摘要

In the present study, simultaneous determination of antazoline hydrochloride (ANZ) and naphazoline hydrochloride (NFZ) in ophthalmic formulations by newly developed ultra-fast liquid chromatographic (UFLC) method was optimized. UFLC separation was performed with ACE Excel 2 C18-PFP column (2 μm, 2.1 x 100 mm) with 0.6 mL/min flow rate of mobile phase which consisted of acetonitrile/phosphate buffer in the ratio of 60:40 (v/v) at 40 ?C and pH adjusted to 3.0 with 0.5 % v/v triethylamine. The detection of ANZ and NFZ was performed at a wavelength of 285 nm and injection of samples was 1.0 μL. The runtime for analysis was 4.5 min and retention times of NFZ and ANZ were found to be 0.92 and 1.86 min, respectively. The calibration graph was linear for ANZ and NFZ with r 2 greater than 0.998 while repeatability and reproducibility (expressed as RSD %) were lower than 1.28 % and 2.14 % respectively. Comparison of UFLC was done with HPLC, UFLC method had remarked advantages over HPLC as run time reduced by 3.4 fold and solvent consumption decreased 5 times. Moreover, detection limits determined by UFLC were 1.5 fold less than HPLC. Force degradation indicated the complete separation of analytes in the presence of degradation products provided the justification of method specificity. The proposed UFLC method was demonstrated to be simple and rapid for the determination of ANZ and NFZ in ophthalmic solutions providing recoveries in the range between 99.6 and 100.4 %.
机译:在本研究中,优化了通过新开发的超快速液相色谱(UFLC)方法同时测定眼科制剂中盐酸安唑啉(ANZ)和盐酸萘甲唑啉(NFZ)的方法。用ACE Excel 2 C18-PFP色谱柱(2μm,2.1 x 100 mm)进行UFLC分离,流动相流速为0.6 mL / min,流动相由乙腈/磷酸盐缓冲液组成,比例为60:40(v / v)在40℃下用0.5%v / v三乙胺将pH调节至3.0。在285 nm的波长下进行ANZ和NFZ的检测,进样量为1.0μL。分析的运行时间为4.5分钟,发现NFZ和ANZ的保留时间分别为0.92和1.86分钟。 ANZ和NFZ的校准曲线是线性的,r 2大于0.998,而重复性和重现性(表示为RSD%)分别低于1.28%和2.14%。 UFLC与HPLC进行比较,UFLC方法比HPLC具有明显的优势,因为运行时间减少了3.4倍,溶剂消耗减少了5倍。此外,通过UFLC测定的检出限比HPLC低1.5倍。强制降解表明存在降解产物的情况下,分析物完全分离,这提供了方法特异性的依据。结果表明,所提出的UFLC方法简便,快速,可测定滴眼剂中的ANZ和NFZ,其回收率在99.6%至100.4%之间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号