首页> 外文期刊>Current Journal of Applied Science and Technology >Validation of the Area1 of Approximate Entropy(a1ApEn) in Empirical Data of Heart Rate
【24h】

Validation of the Area1 of Approximate Entropy(a1ApEn) in Empirical Data of Heart Rate

机译:心率经验数据中近似熵(a1ApEn)Area1的验证

获取原文
           

摘要

Aims: To validate the use of the non-linear estimator a1ApEn in empirical data.Study Design: Comparison of heart rate variability/complexity (HRV/C) between rest and low intensity exercise.Methodology: R-R intervals were obtained from electrocardiogram recordings in 15 healthy volunteers during 30 minutes of rest followed by 30 minutes of treadmill walking (? 4 km/h). The R-R series were linearly detrended, checked for stationarity, and windows of 150 non-overlapping intervals were sequentially extracted. HRV/C estimators were obtained: standard deviation (SDNN), root mean square (RMSSD), power of frequency bands (LF, HF and VHF, i.e., above 0.40 Hz) by STFT, normalized power (nu), a1ApEn. Correlations were studied intra-individual between conditions and intra-population. Additionally, in the Fourier Transform data, phases were randomly shuffled, an inverse transform applied (reconstituted rR-R), and RMSSD and a1ApEn were computed. Finally, the scaling profile of a1ApEn between conditions was addressed.Results: All the HRC/V estimators, except nuLF and nuVHF, showed a decrease in low intensity exercise. For intra-population, all the estimators, except VHF, demonstrated highly significant negative correlations with heart rate. In the reconstituted rR-R series, both RMSSD and a1ApEn increased due to the phase shuffling, while the effect being more intense in a1ApEn. The scaling profile of a1ApEn was compatible with normally distributed random noise in both rest and walk.Conclusion: As is currently known, HRV/C estimators are intrinsically correlated to heart rate, and a1ApEn follows this rule. Differently from what is usually obtained for plain ApEn, here we show a decrease in complexity values with physical effort. Also, the rR-R analysis indicates that a1ApEn is more sensitive to temporal organization than RMSSD. At the same time, the scaling profile indicates that the complexity of heart rate control keeps the same features from rest to walk. Therefore, we show that a1ApEn is a valid tool in time-series analysis of empirical data.
机译:目的:验证非线性估计量a1ApEn在经验数据中的使用研究设计:休息与低强度运动之间心率变异性/复杂性(HRV / C)的比较方法:从15例心电图记录中获得RR间隔健康的志愿者在休息30分钟后,要在跑步机上步行30分钟(?4 km / h)。将R-R系列线性去趋势,检查平稳性,并顺序提取150个非重叠间隔的窗口。获得了HRV / C估计值:标准差(SDNN),均方根(RMSSD),STFT频带(LF,HF和VHF,即0.40 Hz以上)的功率,归一化功率(nu),a1ApEn。在条件和人口内部个体之间进行相关性研究。另外,在傅立叶变换数据中,随机地混相,应用逆变换(重构的rR-R),并计算RMSSD和a1ApEn。最终,解决了条件之间a1ApEn的比例变化曲线。结果:除nuLF和nuVHF外,所有HRC / V估计量均显示出低强度运动的减少。对于人口内部,除VHF外,所有估计量均与心率呈极显着负相关。在重构的rR-R系列中,由于相位改组,RMSSD和a1ApEn均增加,而在a1ApEn中效果更明显。结论a1ApEn的比例分布与休息和行走时的正态分布随机噪声兼容。结论:目前已知,HRV / C估计值与心率内在相关,a1ApEn遵循此规则。与通常从简单的ApEn获得的结果不同,在这里我们显示出随着物理努力而降低了复杂度值。同样,rR-R分析表明a1ApEn比RMSSD对时间组织更敏感。同时,缩放比例曲线表明,心率控制的复杂性使从休息到行走都保持相同的功能。因此,我们表明a1ApEn是经验数据时序分析中的有效工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号