...
首页> 外文期刊>Community Based Medical Journal >Comparison between heater with incubator care in providing warmth to low birth weight newborns
【24h】

Comparison between heater with incubator care in providing warmth to low birth weight newborns

机译:加热器与保育箱在为低出生体重新生儿提供保暖方面的比较

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Prevention of excessive heat loss is fundamental to survival of low birth weight (LBW) newborns. Highly expensive incubator is not available in most of the health care facilities of Bangladesh. Warm cot care by heater or with light bulbs may alternatively help in maintenance of temperature of LBW newborns in health care facilities where incubator is not available. So far i know no such study was conducted before in our country, this study was carried out to show the effectiveness of warm cot care in comparison to incubator care. The present study was cross sectional descriptive type study conducted in the Department of Neonatology, Mymensingh Medical College over a period 1 year from January 2009 to December 2009. Fifty neonates weighing 1200-2000g with gestational age ? 30 weeks to 40 weeks were allocated to an incubator group and similar number with same criteria were taken as cot care group. In cot care group, those babies were selected that are not supposed to cot care due to lack of incubator. The study showed that there were no differences between infants warm cot care versus incubator care. The temperature of the study patients showed that 34(68.0%) and 36(72.0%) maintained normal temperature all the time during hospital stay prior to discharge and rest 16(32.0%) and 14(28.0%) in cot and incubator group respectively became either hypothermic or hyperthermic. Mild hypothermia/cold stress was 7(14.0%) in cot and 4(8.0%) in incubator group. Moderate hypothermia and severe hypothermia was none in both groups. Hyperthermia/fever was 9(18.0%) and 10(20.0%) in cot and incubator group respectively. Analysis reveals that no significant difference was found between two groups. The body temperature of the low birth weight babies (weighing1200-2000g) can be satisfactorily maintained in the low-cost warm cots without the help of incubators which are costly and not available in most of the health care facilities in the developing countries like Bangladesh. DOI: http://dx.doi.org/10.3329/cbmj.v2i2.16691 Community Based Medical Journal 2013 July: Vol.02 No 02: 4-8
机译:预防热量过多流失对于低出生体重(LBW)新生儿的生存至关重要。孟加拉国的大多数医疗机构都没有昂贵的孵化器。在没有保育箱的医疗保健设施中,通过加热器或灯泡对婴儿床进行保暖可能会有助于维持LBW新生儿的温度。到目前为止,我不知道在我国以前没有进行过这样的研究,这项研究的目的是证明与保育箱相比,保暖床的有效性。本研究是从2009年1月至2009年12月在Mymensingh医学院新生儿科进行的横断面描述性类型研究。有50名新生儿的体重在1200-2000g之间,且胎龄高?将30周至40周分配给孵化器组,将具有相同标准的类似数量作为婴儿床护理组。在婴儿床护理组中,选择了由于缺少保育箱而不能进行婴儿床护理的婴儿。研究表明,婴儿保暖床和保育箱之间没有差异。研究患者的体温显示,出院前住院期间一直保持34(68.0%)和36(72.0%)的温度不变,婴儿床和保温箱组分别保持16(32.0%)和14(28.0%)的温度。变为低温或高温。婴儿床轻度低温/冷应激为7(14.0%),孵化器组为4(8.0%)。两组均无中度低温和严重体温过低。婴儿床和保温箱组的热疗/发烧分别为9(18.0%)和10(20.0%)。分析显示两组之间没有发现显着差异。无需保育箱的帮助,就可以在低成本的温暖婴儿床中令人满意地维持低出生体重婴儿(体重在1200-2000g)的体温,而保育箱的价格昂贵,而且在像孟加拉国这样的发展中国家的大多数医疗机构中都没有。 DOI:http://dx.doi.org/10.3329/cbmj.v2i2.16691基于社区的医学杂志2013年7月:Vol.02 No 02:4-8

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号