Boston type I keratoprosthesis-donor cornea interface evaluated by high-definition spectral-domain anterior segment optical coherence tomography

机译:通过高清光谱域前节光学相干断层扫描技术评估波士顿I型角膜修复体-供体角膜界面

获取原文
           

摘要

Background: The purpose of this study was to assess whether the resolution offered by two different, recently commercially available high-resolution, spectral-domain anterior segment optical coherence tomography (AS-OCT) instruments allows for detailed anatomic characterization of the critical device-donor cornea interface in eyes implanted with the Boston type I permanent keratoprosthesis.Methods: Eighteen eyes of 17 patients implanted with the Boston type I keratoprosthesis were included in this retrospective case series. All eyes were quantitatively evaluated using the Cirrus HD-OCT while a subset (five eyes) was also qualitatively imaged using the Spectralis Anterior Segment Module. Images from these instruments were analyzed for evidence of epithelial migration onto the anterior surface of the keratoprosthesis front plate, and presence of a vertical gap between the posterior surface of the front plate and the underlying carrier donor corneal tissue. Quantitative data was obtained utilizing the caliper function on the Cirrus HD-OCT.Results: The mean duration between AS-OCT imaging and keratoprosthesis placement was 29 months. As assessed by the Cirrus HD-OCT, 83% of eyes exhibited epithelial migration over the edge of the front plate. Fifty-six percent of the keratoprosthesis devices displayed good apposition of the device with the carrier corneal donor tissue. When a vertical gap was present (44% of eyes), the mean gap was 40 (range 8–104) microns. The Spectralis Anterior Segment Module also displayed sufficient resolution to allow for similar characterization of the device-donor cornea interface.Conclusion: Spectral-domain AS-OCT permits high resolution imaging of the keratoprosthesis device-donor cornea interface. Both the Cirrus HD-OCT and the Spectralis Anterior Segment module allowed for visualization of epithelial coverage of the device-donor cornea interface, as well as identification of physical gaps. These imaging modalities, by yielding information in regard to integration of the keratoprosthesis with surrounding corneal tissue, may help identify those at risk for keratoprosthesis-related complications, such as extrusion and endophthalmitis, and hence guide clinical management.
机译:背景:本研究的目的是评估由两种不同的,最近可商购的高分辨率,光谱域前节光学相干断层扫描(AS-OCT)仪器提供的分辨率是否允许对关键设备供体进行详细的解剖学表征方法:本回顾性病例系列研究包括了17例波士顿I型永久性角膜修复手术患者的18只眼。使用Cirrus HD-OCT对所有眼睛进行定量评估,同时还使用Spectralis前节模块对定性的子集(五只眼睛)进行成像。分析了来自这些仪器的图像,以了解上皮迁移到角膜假体前板前表面的证据,以及前板后表面和下面的载体供体角膜组织之间是否存在垂直间隙。利用Cirrus HD-OCT上的卡尺功能获得了定量数据。结果:AS-OCT成像与角膜假体植入之间的平均持续时间为29个月。根据Cirrus HD-OCT评估,有83%的眼睛在前板边缘上皮上皮迁移。 56%的角膜假体设备显示该设备与载体角膜供体组织的良好结合。当存在垂直间隙(44%的眼睛)时,平均间隙为40(8-104范围)微米。 Spectralis前节模块还显示了足够的分辨率,可以对装置-供体角膜界面进行类似的表征。结论:光谱域AS-OCT可以对角膜假体装置-供体角膜界面进行高分辨率成像。 Cirrus HD-OCT和Spectralis前节模块都允许可视化设备-供体角膜界面的上皮覆盖范围,并识别物理间隙。这些成像方式通过产生有关角膜假体与周围角膜组织整合的信息,可以帮助识别那些面临角膜假体相关并发症(例如挤压和眼内炎)风险的人,从而指导临床治疗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号