Quantitative Comparison Of Microvascular Metrics On Three Optical Coherence Tomography Angiography Devices In Chorioretinal Disease

机译:脉络膜视网膜疾病中三种光学相干断层扫描血管造影设备上的微血管指标的定量比较

获取原文
           

摘要

Purpose: Optical coherence tomography angiography (OCT-A) has emerged as a novel tool for the non-invasive imaging and evaluation of the retinal microvasculature. There is little existing literature that compares OCT-A microvasculature metrics across different OCT-A devices in chorioretinal diseases. Herein, we examined these metrics on three available OCT-A platforms. Patients and methods: All subjects were scanned on each of three OCT-A devices: Optovue Avanti Angiovue, Topcon DRI-OCT Triton Swept-Source OCT, and Zeiss Cirrus 5000-HD-OCT Angioplex. Two investigators independently measured foveal avascular zone (FAZ) area. Superficial capillary plexus (SCP) and deep capillary plexus (DCP) vessel densities (VD) were calculated from binarized images with ImageJ software. Image quality across devices was qualitatively compared. Interclass correlation coefficient (ICC), Bland-Altman analysis, repeated measures ANOVA, and post-hoc tests were performed for statistical analysis. Results: Thirteen eyes of seven patients with chorioretinal diagnoses were reviewed. ICC for FAZ measurement was 0.95. There was no significant difference in FAZ area across the three devices (p= 0.792). There was a significant difference in the SCP VD between the OCT-A devices (Triton 0.344 ± 0.013, Angiovue 0.323 ± 0.013, Angioplex 0.367 ± 0.014, p 0.05). Significantly greater DCP VD was observed with Angioplex (0.385 ± 0.010) in comparison to both Triton (0.331 ± 0.009) and Angiovue (0.341 ± 0.020). A comparison of image quality revealed that Angiovue gives the highest quality, followed by Angioplex and Triton. Conclusion: Core macular microvasculature metrics are now readily accessible on a variety of available OCT-A devices. While the FAZ can be reliably measured across all three devices in this study, there were significant differences for the vessel density in both the SCP and DCP. As a result, clinicians should be careful when comparing microvasculature metrics across different devices when using patient data in multicenter research investigations and clinical trials.
机译:目的:光学相干断层扫描血管造影(OCT-A)已经成为一种用于视网膜微脉管系统无创成像和评估的新型工具。很少有文献比较脉络膜视网膜疾病中不同OCT-A设备上的OCT-A微脉管系统指标。本文中,我们在三个可用的OCT-A平台上检查了这些指标。患者和方法:所有受试者均在以下三种OCT-A设备上进行扫描:Optovue Avanti Angiovue,Topcon DRI-OCT Triton扫频OCT和Zeiss Cirrus 5000-HD-OCT Angioplex。两名研究者独立测量了中央凹无血管区域(FAZ)面积。使用ImageJ软件从二值化图像计算出浅毛细血管丛(SCP)和深毛细血管丛(DCP)血管密度(VD)。定性比较了跨设备的图像质量。进行了类间相关系数(ICC),Bland-Altman分析,重复测量ANOVA和事后检验进行统计分析。结果:回顾了7例脉络膜视网膜病患者的13眼。用于FAZ测量的ICC为0.95。三种设备的FAZ面积均无显着差异(p = 0.792)。 OCT-A设备之间的SCP VD存在显着差异(Triton 0.344±0.013,Angiovue 0.323±0.013,Angioplex 0.367±0.014,p <0.05)。与Triton(0.331±0.009)和Angiovue(0.341±0.020)相比,Angioplex(0.385±0.010)观察到的DCP VD明显更高。比较图像质量后发现,Angiovue的图像质量最高,其次是Angioplex和Triton。结论:现在可以在各种可用的OCT-A设备上轻松获得核心的黄斑微脉管系统指标。尽管在本研究中可以在所有三个设备上可靠地测量FAZ,但SCP和DCP中的血管密度存在显着差异。因此,在多中心研究调查和临床试验中使用患者数据时,临床医生在比较不同设备上的微脉管指标时应格外小心。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号