Aim: Our study was conducted to evaluate whether higher temperature leads to increased – or wider – scroll widths of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft. Purpose: To investigate the effects of temperature and fluid media on the DMEK donor graft scroll widths. Materials and methods: This research work was a laboratory investigation. Baseline cell count was taken via specular microscopy for the donor corneas at room temperature (20°C–25°C). The endothelium sides of the donor corneas were stained with Trypan Blue Solution 0.4% for 30?s, and the Descemet’s membranes were stripped. The DMEK donor grafts were placed into three different fluid media – Optisol?, Balanced Salt Solution (BSS), and BSS PLUS? (BSS Plus). The DMEK donor grafts were then transferred into cold temperature (4°C) for 60 min, after which the donor grafts’ scroll widths were examined and measured. The donor grafts were then warmed in the incubator and brought to physiological temperature (35°C–37°C), and their scroll widths were examined and measured again. Results: In 30 measurements of ten tissues across three temperature and fluid conditions, the average scroll width measured 1.73?mm, ranging from 1.1 to 2.9?mm. In a mixed linear model, the scroll widths increased with temperature ( P =0.02). There was no significant difference in scroll widths among the three solutions ( P =0.84, mixed linear model). Conclusion: We observed an increase in DMEK donor graft scroll widths with higher temperatures. The usage of BSS Plus as media solution could also lead to smaller DMEK donor graft scroll widths, compared with BSS, but our study does not establish this.
机译:目的:我们进行了研究,以评估较高的温度是否会导致Descemet的膜内皮角膜移植术(DMEK)供体移植物的滚动宽度增大(或更宽)。目的:研究温度和流体介质对DMEK供体移植物涡旋宽度的影响。材料和方法:这项研究工作是实验室研究。在室温(20°C–25°C)下通过镜检显微镜对供体角膜进行基线细胞计数。用0.4%的锥虫蓝溶液将供体角膜的内皮侧染色30?s,并剥去Descemet膜。将DMEK供体移植物置于三种不同的流体介质中-Optisol ?,平衡盐溶液(BSS)和BSS PLUS ?(BSS Plus)。然后将DMEK供体移植物转移到低温(4°C)中60分钟,然后检查并测量供体移植物的涡旋宽度。然后将供体移植物在培养箱中加热,使其达到生理温度(35°C–37°C),并检查并再次测量其涡旋宽度。结果:在三种温度和流体条件下对十个组织进行的30次测量中,平均滚动宽度为1.73?mm,范围为1.1至2.9?mm。在混合线性模型中,滚动宽度随温度增加而增加(P = 0.02)。三种解决方案之间的滚动宽度没有显着差异(P = 0.84,混合线性模型)。结论:我们观察到较高温度下DMEK供体移植物涡旋宽度的增加。与BSS相比,使用BSS Plus作为培养基溶液还可以导致较小的DMEK供体移植物涡旋宽度,但我们的研究没有证实这一点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号