The use of imbricated sutures in radioactive plaque brachytherapy surgery

机译:混合缝合线在放射性斑块近距离放射治疗中的应用

获取原文
           

摘要

Abstract: This paper describes a new technique to suture the radioactive plaque to sclera. The radioactive plaque is conventionally sutured to the sclera using 5/0 nylon sutures. The imbricated suture technique involves using a 1/0 silk or 2/0 mersilene suture imbricated with the 5/0 nylon suture when the nylon suture is tied and cut. The imbricated suture technique allows easy identification of the plaque at removal and provides a surface that separates the 5/0 nylon from the surface of the eyelet platform, making suture cutting easier and safer. The radiation exposure times ranged from 9.1 minutes to 14 minutes (mean: 10.8 minutes) during plaque insertion and from 2.8 to 3.3 minutes (mean: 3.0 minutes) during plaque removal with the imbricated suture technique. This technique may decrease radiation exposure time and may prevent inadvertent scleral damage.
机译:摘要:本文介绍了一种将放射性斑块缝合至巩膜的新技术。通常使用5/0尼龙缝线将放射性斑块缝合到巩膜。缝合线技术涉及在尼龙缝合线被捆扎和切割时,使用与5/0尼龙缝合线交织在一起的1/0真丝或2/0 mersilene缝合线。缝合线缝合技术可轻松识别去除时的斑块,并提供一个将5/0尼龙与孔眼平台表面隔开的表面,从而使缝合线切割更容易,更安全。斑块插入过程中的辐射暴露时间范围为9.1分钟至14分钟(平均:10.8分钟),而采用固定缝合技术去除斑块过程中的辐射暴露时间为2.8至3.3分钟(平均值:3.0分钟)。该技术可以减少辐射暴露时间,并可以防止意外的巩膜损伤。