In this paper, the bending resistance of three metal-concrete composite beams was compared in real car fires in an open car park. Steel and concrete composite beams are often used for the construction of ceilings in multi-storey car parks. The authors made an attempt to evaluate how the replacement of a non-alloy steel girder with a stainless steel or aluminium alloy girder affects the bending resistance of a composite beam under fire conditions. The analysed beams were not fire-protected. They consisted of a concrete slab and a girder made of: non-alloy ( carbon ) S235J2 (1.0117) steel, X6CrNiMoTi17- 12-2 (1.4571) stainless steel, and AW-6061 T6 (EN AW-Al Mg1SiCu) aluminium alloy.
机译:本文比较了在露天停车场的真实汽车火灾中,三种金属混凝土复合梁的抗弯强度。钢和混凝土复合梁通常用于多层停车场的天花板施工。作者试图评估用不锈钢或铝合金梁代替非合金钢梁如何在火灾条件下影响复合梁的抗弯性。被分析的光束没有防火。它们由混凝土板和大梁组成,这些大梁由以下材料制成:非合金(碳)S235J2(1.0117)钢,X6CrNiMoTi17-12-2(1.4571)不锈钢和AW-6061 T6(EN AW-Al Mg1SiCu)铝合金。