Objective: The aim of our study was to compare the results obtained from different methods, which are used to determine the susceptibility to antimicrobials, and to determine the agreement between them. Materials and Methods: A total of 397 strains consisting of 329 gram negative and 68 gram positive bacteria that were isolated from urine samples and identification and antibiogram of which were performed by automated systems, were included in the study. The results obtained from broth microdilution, E test, VITEK and disk diffusion were compared. Results: Our antimicrobial susceptibility test results in gram negative bacteria showed a categorical agreement of 93.3% with a very major error rate of 1.5 in disk diffusion test, while a categorical agreement of 90% with a very major error rate of 2.2% in Vitek 2 test. The agreement for E test was 95.3% with a very major error rate of 1.1. In the antimicrobial susceptibility test of gram positive bacteria, the rate of agreement for disk diffusion, E test and Vitek 2 was 97.2%, 98.4% and 95.4% respectively. Very major error rate was found % 1.5 ve % 2.6 in disk diffusion and Vitek 2, respectively, while no very major error was found in E test. Conclusions: In conclusion, our data suggest that disk diffusion test, Vitek 2 system and E test test are accurate and acceptable for antibiotic susceptibility tests of gram positive bacteria. The agreement rate of BMD and E test methods was found above 90% for all antibiotics, and it was reached a conclusion that the susceptibility results of gram negative bacteria for ceftriaxone and nitrofurantoin obtained from VITEK; the susceptibility results of disk diffusion test for ceftriaxone and ciprofloxacin should be confirmed by a more reliable method.
机译:目的:我们的研究目的是比较从不同方法获得的结果,这些方法用于确定对抗生素的敏感性,并确定它们之间的一致性。材料与方法:研究共包括397株菌株,由尿液样本中分离出的329克阴性细菌和68克阳性细菌组成,并通过自动化系统进行了鉴定和抗菌谱分析。比较了肉汤微稀释,E检验,VITEK和圆盘扩散得到的结果。结果:我们在革兰氏阴性细菌中的抗菌药敏试验结果表明,在纸片扩散试验中,分类符合率为93.3%,非常大的错误率为1.5;而在Vitek 2中,分类符合率为90%,非常大的错误率为2.2%。测试。 E测试的一致性为95.3%,非常大的错误率为1.1。在革兰氏阳性细菌的抗菌药敏试验中,纸片扩散,E试验和Vitek 2的符合率分别为97.2%,98.4%和95.4%。在磁盘扩散和Vitek 2中发现非常大的错误率分别为%ve%2.6和%,而在E测试中没有发现非常大的错误率。结论:总之,我们的数据表明,圆盘扩散测试,Vitek 2系统和E测试测试对于革兰氏阳性细菌的抗生素敏感性测试是准确且可以接受的。所有抗生素的BMD和E测试方法的符合率均在90%以上,并得出结论:革兰氏阴性菌对从VITEK获得的头孢曲松和硝基呋喃妥因的敏感性结果;头孢曲松和环丙沙星的纸片扩散试验的药敏结果应通过更可靠的方法来确认。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号