首页> 外文期刊>Chemical and Pharmaceutical Bulletin >Simple and Rapid HPLC-UV Method Using an Ultrafine Particle Octadecylsilane for Determination of Residual Fentanyl in Applied Durotep? MT Transdermal Matrix Patches and Its Clinical Application
【24h】

Simple and Rapid HPLC-UV Method Using an Ultrafine Particle Octadecylsilane for Determination of Residual Fentanyl in Applied Durotep? MT Transdermal Matrix Patches and Its Clinical Application

机译:使用超微粒十八烷基硅烷的简单,快速HPLC-UV方法测定所应用的Durotep®中的残留芬太尼MT透皮基质贴剂及其临床应用

获取原文
           

摘要

A few complicated and time-consuming methods are available for the determination of residual fentanyl in Durotep? MT transdermal patches, however, their application to clinical settings is limited. The aim of this study was to develop a simple and rapid HPLC-UV method using an ultrafine particle octadecylsilane (ODS) for the determination of residual fentanyl in applied Durotep? MT transdermal matrix patches. Patch extraction involved sonicating a shredded Durotep? MT patch in acetonitrile for 15?min. Fentanyl separation was completed within 2?min using a 2.3-μm particle ODS column (50×4.6?mm i.d.) at a flow rate of 1.5?mL/min. No peaks interfering with fentanyl (1.27?min) and papaverine (0.89?min) as an internal standard were observed. The calibration curve for fentanyl was linear over the range of 0.015—9.0?mg as a Durotep? MT patch. The intra- and inter-assay precisions and accuracies of each patch were within 5.3% and 103.9—110.5% and within 8.2% and 97.1—104.3%, respectively. The validated method was applied to determine residual fentanyl in Durotep? MT patches used in 35 cancer patients. Although the plasma fentanyl concentration was significantly correlated with its measured absorption rate, the measured absorption rate normalized fentanyl concentration showed a large inter-individual variation. The validated simple and rapid HPLC-UV method established in the present study is helpful for evaluating the absorption rate of fentanyl in patients receiving Durotep? MT patches.
机译:目前,有几种复杂而耗时的方法可用于测定Durotep ? MT透皮贴剂中的残留芬太尼,但其在临床环境中的应用受到限制。本研究的目的是开发一种使用超细颗粒十八烷基硅烷(ODS)的简单,快速的HPLC-UV方法,用于测定应用的Durotep?s MT透皮基质贴剂中的残留芬太尼。补丁提取包括将切碎的Durotep ? MT补丁在乙腈中超声处理15分钟。使用2.3μm的ODS颗粒色谱柱(内径50×4.6?mm)以1.5?mL / min的流速在2?min内完成芬太尼的分离。没有观察到干扰芬太尼(1.27?min)和罂粟碱(0.89?min)作为内标的峰。在Durotep ? MT贴剂中,芬太尼的校正曲线在0.015–9.0?mg范围内呈线性。每个贴片的批内和批间精密度分别在5.3%和103.9-110.5%之内,在8.2%和97.1-104.3%之内。验证的方法用于测定35例癌症患者的Durotep ? MT贴剂中的残留芬太尼。尽管血浆芬太尼浓度与其测得的吸收率显着相关,但测得的吸收率归一化芬太尼浓度显示出较大的个体差异。本研究建立的经过验证的简便快速的HPLC-UV方法有助于评估接受Durotep ? MT贴剂的患者中芬太尼的吸收率。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号