首页> 外文期刊>Case Studies in Engineering Failure Analysis >Failure investigation of super heater tubes of coal fired power plant
【24h】

Failure investigation of super heater tubes of coal fired power plant

机译:燃煤电厂过热器故障研究

获取原文

摘要

Cause of failure of two adjacent super heater tubes made of Cr-Mo steel of a coal based 60MW thermal power plant has been portrayed in present investigation. Oxide deposits were found on internal surface of tubes. Deposits created significant resistance to heat transfer and resulted in undesirable rise in component temperature. This situation, in turn, aggravated the condition of gas side that was exposed to high temperature. Localized heating coarsened carbides as well as propelled precipitation of new brittle phases along grain boundary resulting in embrittlement of tube material. Continuous exposure to high temperature softened the tube material and tube wall was thinned down with bulging toward outside. Creep void formation along grain boundary was observed and steered intergranular cracking. All these effects contributed synergistically and tubes were failed ultimately due to overload under high Hoop stress.
机译:在本次调查中,已描绘出两个相邻的由60兆瓦煤基热电厂的Cr-Mo钢制成的过热器管发生故障的原因。在管子的内表面发现了氧化物沉积物。沉积物对传热产生很大的阻力,并导致部件温度出现不希望的升高。反过来,这种情况加剧了暴露于高温的气体侧的状况。局部加热使碳化物粗化,并促使新的脆性相沿晶界析出,导致管材脆化。连续暴露在高温下会使管材变软,并且管壁变薄,并向外鼓胀。观察到沿晶界的蠕变空洞形成,并引起晶间开裂。所有这些效应协同作用,并且由于高环向应力下的超载,最终导致管失效。